Modiolar proximity of three perimodiolar cochlear implant electrodes

被引:41
作者
Balkany, TJ [1 ]
Eshraghi, AA [1 ]
Yang, N [1 ]
机构
[1] Univ Miami, Ear Inst, Miami, FL 33136 USA
关键词
cochlear implants; computer morphometrics; videofluoroscopy;
D O I
10.1080/00016480260000021
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
A new generation of cochlear implant electrodes has been designed to position the stimulating contacts close to the modiolus in order to reduce power consumption and increase stimulation selectivity. The purpose of this study was to assess electrode position in the cochlea for three recently designed electrodes. Fifteen cadaveric temporal bones were implanted with one of three perimodiolar electrode arrays: Nucleus Contour; Med-El Combi40+ PM (developmental version); and Clarion HiFocus II. Image-enhanced videofluoroscopy and computer morphometrics were used to assess stimulating contact position relative to the modiolus. The mean distance (+/-1 standard deviation) to the modiolus for all electrode contacts was 0.33 (+/-0.24), 0.30 (+/-0.27) and 0.16 mm (+/-0.19) for the Contour, Combi40+ PM and HiFocus II arrays, respectively. In addition, dynamic videofluoroscopy was used to correlate device-specific insertion characteristics with contact-to-modiolus distance. All three devices were successful in terms of locating electrode contacts very close to the modiolar wall.
引用
收藏
页码:363 / 369
页数:7
相关论文
共 11 条
[1]  
Cohen LT, 1996, AM J OTOL, V17, P859
[2]   A silastic positioner for a modiolus-hugging position of intracochlear electrodes: Electrophysiologic effects [J].
Cords, SM ;
Reuter, G ;
Issing, PR ;
Sommer, A ;
Kuzma, J ;
Lenarz, T .
AMERICAN JOURNAL OF OTOLOGY, 2000, 21 (02) :212-217
[3]   The Clarion electrode positioner: Temporal bone studies [J].
Fayad, JN ;
Luxford, W ;
Linthicum, FH .
AMERICAN JOURNAL OF OTOLOGY, 2000, 21 (02) :226-229
[4]  
Gstoettner W, 1999, ACTA OTO-LARYNGOL, V119, P229
[5]   Computer-aided three-dimensional reconstruction in human cochlear maps: Measurement of the lengths of organ of corti, outer wall, inner wall, and Rosenthal's canal [J].
Kawano, A ;
Seldon, HL ;
Clark, GM .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1996, 105 (09) :701-709
[6]  
Ketten DR, 1998, ANN OTO RHINOL LARYN, V107, P1
[7]   Strategies to improve electrode positioning and safety in cochlear implants [J].
Rebscher, SJ ;
Heilmann, M ;
Bruszewski, W ;
Talbot, NH ;
Snyder, RL ;
Merzenich, MM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (03) :340-352
[8]   The Nucleus Contour electrode array: A radiological and histological study [J].
Richter, B ;
Aschendorff, A ;
Lohnstein, P ;
Husstedt, H ;
Nagursky, H ;
Laszig, R .
LARYNGOSCOPE, 2001, 111 (03) :508-514
[9]  
ROLAND JT, 2000, AM J OTOL, V1, P18
[10]   Novel intracochlear electrode positioner: Effects on electrode position [J].
Yang, NW ;
Hodges, AV ;
Balkany, TJ .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2000, 109 (12) :18-20