Anion-exchange separation and determination of bisphosphonates and related analytes by post-column indirect fluorescence detection

被引:59
作者
Lovdahl, MJ
Pietrzyk, DJ [1 ]
机构
[1] Univ Iowa, Dept Chem, Iowa City, IA 52242 USA
[2] Parke Davis Pharmaceut, Ann Arbor, MI 48105 USA
关键词
derivatization; LC; detection; indirect fluorescence detection; fluorescence detection; bisphosphonates; phosphonates; inositol phosphate;
D O I
10.1016/S0021-9673(99)00622-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Bisphosphonic acids and their salts can be detected after their liquid chromatographic separation by post-column indirect fluorescence detection (IFD). After separation the analyte is combined with the highly fluorescent Al3+-morin (2',3,4',5,7-pentahydroxyflavone) solution and fluorescence decreases because of the formation of the nonfluorescent Al3+-bisphosphonate complex. The decrease in fluorescence is proportional to the amount of bisphosphonate present. Separation of the multivalent anionic bisphosphonate analytes from other anions and sample matrix is achieved on a strong base anion-exchange column with a strong, basic eluent. The post-column reaction variables, which influence IFD, are identified and optimized for the detection of the bisphosphonates after separation on the anion exchanger. The method is selective, since only a few anions will undergo a reaction with the Al3+-morin solution, and sensitive, detection limit for difluoromethylene bisphosphonate, F2MDP, is 4 ng for S/N = 3. The separation-IFD method can be applied to the determination of bisphosphonates, such as F2MDP, ethane-1-hydroxy-1,1-bisphosphonic acid, dichloromethylene bisphosphonic acid, 4-amino-1-hydroxybutane-1,1-bisphosphonic acid, in biological samples. The separation-IFD method is also applicable to the detection of inositol phosphate anions. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:143 / 152
页数:10
相关论文
共 34 条
[11]  
FORBES KA, 1989, ADV CHROMATOGR, V1, P487
[12]  
ISMAIL Z, 1987, J CHROMATOGR, V404, P372
[13]   DETERMINATION OF 4-AMINO-1-HYDROXYBUTANE-1,1-BISPHOSPHONIC ACID IN URINE BY AUTOMATED PRECOLUMN DERIVATIZATION WITH 2,3-NAPHTHALENE DICARBOXYALDEHYDE AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
KLINE, WF ;
MATUSZEWSKI, BK ;
BAYNE, WF .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 534 :139-149
[14]   HPLC ANALYSIS OF AN AMINO BISPHOSPHONATE IN PHARMACEUTICAL FORMULATIONS USING POSTCOLUMN DERIVATIZATION AND FLUORESCENCE DETECTION [J].
KWONG, E ;
CHIU, AMY ;
MCCLINTOCK, SA ;
COTTON, ML .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1990, 28 (11) :563-566
[15]  
LAND DB, 1966, MIKROCHIM ACTA, V6, P1013
[16]   DETERMINATION OF ETHANE-1-HYDROXY-1,1-DIPHOSPHONIC ACID (EHDP) IN HUMAN FECES AND URINE [J].
LIGGETT, SJ .
BIOCHEMICAL MEDICINE, 1973, 7 (01) :68-77
[17]   LIQUID-CHROMATOGRAPHY AND POSTCOLUMN INDIRECT DETECTION OF GLYPHOSATE [J].
LOVDAHL, MJ ;
PIETRZYK, DJ .
JOURNAL OF CHROMATOGRAPHY, 1992, 602 (1-2) :197-204
[18]  
LOWIK CWGM, 1988, J BONE MINER RES, V3, P185
[19]   LIQUID-CHROMATOGRAPHIC SEPARATION OF PHOSPHORUS OXO ACIDS AND OTHER ANIONS WITH POSTCOLUMN INDIRECT FLUORESCENCE DETECTION BY ALUMINUM MORIN [J].
MEEK, SE ;
PIETRZYK, DJ .
ANALYTICAL CHEMISTRY, 1988, 60 (14) :1397-1400
[20]  
PIETRZYK DJ, 1990, ADV ION CHROMATOGRAP, V2, P255