Tandem mass spectrometry in quadrupole ion trap and ion cyclotron resonance mass spectrometers

被引:23
作者
Payne, AH [1 ]
Glish, GL [1 ]
机构
[1] Univ N Carolina, Dept Chem, Chapel Hill, NC 27599 USA
来源
BIOLOGICAL MASS SPECTROMETRY | 2005年 / 402卷
关键词
D O I
10.1016/S0076-6879(05)02004-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Instruments that trap ions in a magnetic and/or electric field play a very important role in the analysis of biomolecules. The two predominant instruments in the category of trapping instrument are the quadrupole ion trap mass spectrometer (QIT-MS) and the ion cyclotron resonance (ICR) MS. The latter is also commonly called Fourier transform MS (FF-MS). The QIT is an inexpensive, simple, and rugged MS used for various routine applications. The ICR-MS is an expensive, high-performance instrument with figures of merit for resolution and mass accuracy surpassing all other mass spectrometers. This chapter covers the basic principles of operation of these instruments, including the trapping/manipulation/detection of ions and various approaches used to activate ions to perform tandem mass spectrometry experiments.
引用
收藏
页码:109 / 148
页数:40
相关论文
共 96 条
[1]  
Badman ER, 1999, J MASS SPECTROM, V34, P889, DOI 10.1002/(SICI)1096-9888(199908)34:8<889::AID-JMS848>3.0.CO
[2]  
2-C
[3]   FOURIER-TRANSFORM ELECTROSPRAY INSTRUMENTATION FOR TANDEM HIGH-RESOLUTION MASS-SPECTROMETRY OF LARGE MOLECULES [J].
BEU, SC ;
SENKO, MW ;
QUINN, JP ;
WAMPLER, FM ;
MCLAFFERTY, FW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (07) :557-565
[4]   ION TRAPPING AND MANIPULATION IN A TANDEM TIME-OF-FLIGHT-FOURIER TRANSFORM MASS-SPECTROMETER [J].
BEU, SC ;
LAUDE, DA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 104 (02) :109-127
[5]   CONTROL OF ION KINETIC-ENERGY IN ION-CYCLOTRON RESONANCE SPECTROMETRY - VERY-LOW-ENERGY COLLISION-INDUCED DISSOCIATION [J].
BOERING, KA ;
ROLFE, J ;
BRAUMAN, JI .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (04) :303-305
[6]   THE ACCURACY OF HEAVY-ION MASS MEASUREMENTS USING TIME OF FLIGHT-ION CYCLOTRON-RESONANCE IN A PENNING TRAP [J].
BOLLEN, G ;
MOORE, RB ;
SAVARD, G ;
STOLZENBERG, H .
JOURNAL OF APPLIED PHYSICS, 1990, 68 (09) :4355-4374
[7]  
Boué SM, 2000, RAPID COMMUN MASS SP, V14, P1391, DOI 10.1002/1097-0231(20000815)14:15<1391::AID-RCM36>3.0.CO
[8]  
2-O
[9]   FRAGMENTATION OF OLIGOPEPTIDE IONS USING ULTRAVIOLET-LASER RADIATION AND FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
BOWERS, WD ;
DELBERT, SS ;
HUNTER, RL ;
MCIVER, RT .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1984, 106 (23) :7288-7289
[10]   THE INFINITY CELL - A NEW TRAPPED-ION CELL WITH RADIOFREQUENCY COVERED TRAPPING ELECTRODES FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
CARAVATTI, P ;
ALLEMANN, M .