Gold-coated capillary based 2,4-dichlorophenoxyacetic acid chemi-lumincscent assays:: possibilities towards multianalysis

被引:9
作者
Ramanathan, K [1 ]
Dzgoev, A [1 ]
Svitel, J [1 ]
Jönsson, BR [1 ]
Danielsson, B [1 ]
机构
[1] Lund Univ, Ctr Chem & Chem Engn, Dept Pure & Appl Biochem, S-22100 Lund, Sweden
关键词
capillaries; assays; acid;
D O I
10.1016/S0956-5663(01)00296-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The application of gold-coated glass capillaries for the design of a sensitive chemiluminescent immunoassay for 2,4-dichlorophenoxyacetic acid (2,4-D) is reported. The gold coating on the glass capillaries has been partially characterized and its effect on enhancing the signal intensity has been measured. A simple photo-multiplier tube-based photon detector is used for this purpose. At least three times improvement in the signal intensity is observed compared to uncoated glass capillaries, with a consequent improvement in the sensitivity of detection. Using such gold-coated glass capillaries, 2,4-D in the range 10(-9) to 10(-13) mol/l is detectable at a precision of +/-15% (CV%) and a limit of detection of 10(-15) mol/l is achievable. The possibility of using such gold-coated capillaries with a portable multianalytical set-up for field studies is also demonstrated. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:283 / 288
页数:6
相关论文
共 18 条
  • [1] High-sensitivity assay for pesticide using a peroxidase as chemiluminescent label
    Drgoev, AB
    Gazaryan, IG
    Lagrimini, LM
    Ramanathan, K
    Danielsson, B
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (22) : 5258 - 5261
  • [2] Optimization of a charge coupled device imaging enzyme linked immune sorbent assay and supports for the simultaneous determination of multiple 2,4-D samples
    Dzgoev, A
    Mecklenburg, M
    Xie, B
    Miyabayashi, A
    Larsson, PO
    Danielsson, B
    [J]. ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) : 87 - 93
  • [3] Kinetic determination of 2,4-dichlorophenoxyacetic acid by stopped-flow fluorescence polarization immunoassay
    Eremin, SA
    Matveeva, EG
    Gómez-Hens, A
    Pérez-Bendito, D
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1998, 71 (02) : 137 - 146
  • [4] Gazaryan IG, 1998, BIOCHEMISTRY-MOSCOW+, V63, P600
  • [5] Improved direct piezoelectric biosensors operating in liquid solution for the competitive label-free immunoassay of 2,4-dichlorophenoxyacetic acid
    Horacek, J
    Skladal, P
    [J]. ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) : 43 - 50
  • [6] CAPILLARY ENZYME-IMMUNOASSAY WITH ELECTROCHEMICAL DETECTION FOR THE DETERMINATION OF ATRAZINE IN WATER
    JIANG, TB
    HALSALL, HB
    HEINEMAN, WR
    GIERSCH, T
    HOCK, B
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1995, 43 (04) : 1098 - 1104
  • [7] JURAJ S, 2000, BIOSENS BIOELECTRON, V15, P411
  • [8] Immunosensor for 2,4-dichlorophenoxyacetic acid in aqueous organic solvent soil extracts
    Kröger, S
    Setford, SJ
    Turner, APF
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (23) : 5047 - 5053
  • [9] A multi-band capillary immunosensor
    Misiakos, K
    Kakabakos, SE
    [J]. BIOSENSORS & BIOELECTRONICS, 1998, 13 (7-8) : 825 - 830
  • [10] CCD-camera based capillary chemiluminescent detection of retinol binding protein
    Momeni, N
    Ramanathan, K
    Larsson, PO
    Danielsson, B
    Bengmark, S
    Khayyami, M
    [J]. ANALYTICA CHIMICA ACTA, 1999, 387 (01) : 21 - 27