Position of the acetabular cup - accuracy of radiographic calculation compared to CT-based measurement

被引:139
作者
Kalteis, T
Handel, M
Herold, T
Perlick, L
Paetzel, C
Grifka, J
机构
[1] Univ Regensburg, Asklepios Klinikum Bad Abbach, Dept Orthopaed Surg, D-93077 Bad Abbach, Germany
[2] Univ Regensburg, Inst Radiol, D-8400 Regensburg, Germany
关键词
hip arthroplasty; acetabular cup; anteversion; inclination; computer-assisted surgery;
D O I
10.1016/j.ejrad.2005.10.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Objective: A variety of mathematical and trigonometric methods has been described for determining the position of the acetabular cups from conventional radiographs. However, these formulae are subject to unduly large inaccuracies. The aim of the study was to compare the reliability and the accuracy of radiological and CT-based determination of acetabular cup position. Materials and methods: The positions of acetabular cups of 31 patients were calculated in conventional plain radiographs of the hip using the method described by Widmer [Widmer K.H. A simplified method to determine acetabular cup anteversion from plain radiographs. J Arthroplasty 2004;19(3):387-90]. Further, in all patients computed tomograms of the pelvis were performed and the cup position was measured with the aid of a CT-based computer-assisted navigation software. As reference values inclination and anteversion of the cups were calculated in 3D reconstructions of the pelvis with the aid of an image processing software. Results: The radiological measurement as well as the CT-based method showed good intra- and inter-observer reliability and no significant difference in the calculation of the inclination (p = 0.409). However, CT-based determination of anteversion was significantly more exact than radiological measurement (p < 0.001). The calculation of the cup anteversion from the X-rays showed serious deviations from the reference method and a substantial error range (X-ray: mean deviation + 1.74 degrees, range - 16.6 degrees to +29.8 degrees, S.D. +/- 9.32 degrees; CT-based: mean deviation -0.74 degrees, range -6.6 degrees to +5.3 degrees, S.D. +/- 12.87). Conclusion: For any clinical problem or for clinical studies in which acetabular positions of acetabular cups have to be exactly determined, CT-based measuring methods are obviously the method of choice. Evaluations based only on conventional plain X-rays and calculation of the acetabular cup position using the formula described by Widmer must be regarded as unreliable, particularly, because of problems in measuring the anteversion. (C) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:294 / 300
页数:7
相关论文
共 18 条
[1]
ANTEVERSION OF THE ACETABULAR CUP - MEASUREMENT OF ANGLE AFTER TOTAL HIP-REPLACEMENT [J].
ACKLAND, MK ;
BOURNE, WB ;
UHTHOFF, HK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (03) :409-413
[2]
C-arm based navigation in total hip arthroplasty -: background and clinical experience [J].
Grützner, PA ;
Zheng, G ;
Langlotz, U ;
von Recum, J ;
Nolte, LP ;
Wentzensen, A ;
Widmer, KH ;
Wendl, K .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2004, 35 :90-95
[3]
RADIOGRAPHIC CALCULATION OF ANTEVERSION IN ACETABULAR PROSTHESES [J].
HASSAN, DM ;
JOHNSTON, GHF ;
DUST, WNC ;
WATSON, LG ;
CASSIDY, D .
JOURNAL OF ARTHROPLASTY, 1995, 10 (03) :369-372
[4]
HERRLIN K, 1988, ACTA RADIOL, V29, P357
[5]
Accuracy of an image-free cup navigation system -: an anatomical study [J].
Kalteis, T ;
Beckmann, J ;
Herold, T ;
Zysk, S ;
Bäthis, H ;
Perlick, L ;
Grifka, J .
BIOMEDIZINISCHE TECHNIK, 2004, 49 (09) :257-262
[6]
THE DEFINITION AND MEASUREMENT OF ACETABULAR ORIENTATION [J].
MURRAY, DW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (02) :228-232
[7]
A new CT method for measuring cup orientation after total hip arthroplasty - A study of 10 patients [J].
Olivecrona, H ;
Weidenhielm, L ;
Olivecrona, L ;
Beckman, MO ;
Stark, A ;
Noz, ME ;
Maguire, GQ ;
Zeleznik, MP ;
Svensson, L ;
Jonson, T .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (03) :252-260
[8]
The influence of patient-related factors and the position of the acetabular component on the rate of dislocation after total hip replacement [J].
Paterno, SA ;
Lachiewicz, PF ;
Kelley, SS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (08) :1202-1210
[9]
RADIOLOGIC EVALUATION OF THE POSITION OF THE ACETABULAR COMPONENT OF THE TOTAL HIP-PROSTHESIS [J].
PETTERSSON, H ;
GENTZ, CF ;
LINDBERG, HO ;
CARLSSON, AS .
ACTA RADIOLOGICA-DIAGNOSIS, 1982, 23 (03) :259-263
[10]
CAUSES OF DISLOCATION OF TOTAL HIP-ARTHROPLASTY - CT STUDY OF COMPONENT ALIGNMENT [J].
PIERCHON, F ;
PASQUIER, G ;
COTTEN, A ;
FONTAINE, C ;
CLARISSE, J ;
DUQUENNOY, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (01) :45-48