Improved PSD and CID on a MALDI TOFMS

被引:17
作者
Hoteling, AJ
Owens, KG
机构
[1] Drexel Univ, Dept Chem, Philadelphia, PA 19104 USA
[2] Eastman Kodak Co, Imaging Mat & Media R&D, Rochester, NY USA
关键词
D O I
10.1016/j.jasms.2003.12.004
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The influence of several instrument-operating parameters on the product-ion resolution and mass accuracy in matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) post-source decay (PSD) and collision-induced dissociation (CID) experiments is reported. Voltages commonly applied to the reflectron for PSD and CID experiments were found to be non-ideal; optimization of these voltages resulted in better resolution across each segment of the measured PSD spectrum. Mass resolution, calculated as M/DeltaM (FWHM) for the production peaks, was as high as 2500. Additionally, precursor-ion selection and segment mass range setup were each found to have dramatic influences on product-ion mass accuracy. An understanding of the influence of these variables aided in the interpretation of (a-NH3) and (b-NH3) ions observed in the PSD/CID spectra of a number of peptides. In addition, product ions resulting from coincidence peaks in the precursor-ion selection window were found to be a general problem. With the improvements to resolution and optimization of these mass accuracy variables, the mass accuracy of product ions from MALDI TOF PSD and CID experiments was tested with several reference materials, including the peptides Substance P, bradykinin, angiotensin I, and angiotensin II and the synthetic polymers poly(methyl methacrylate) and polystyrene. The absolute error (Da) for each test material was, on average, below 0.1 Da, demonstrating a significant improvement in mass accuracy using the improved operational parameters and an extension of the use of poly(ethylene glycol) (PEG) as a mass calibrant for the PSD/CID spectra. (C) 2004 American Society for Mass Spectrometry.
引用
收藏
页码:523 / 535
页数:13
相关论文
共 29 条
[1]   Poly(propylene imine) dendrimer conformations in the gas phase: a tandem mass spectrometry study [J].
Adhiya, A ;
Wesdemiotis, C .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 214 (01) :75-88
[2]   NEW METHOD FOR METASTABLE ION STUDIES WITH A TIME OF FLIGHT MASS-SPECTROMETER - FUTURE APPLICATIONS TO MOLECULAR-STRUCTURE DETERMINATIONS [J].
DELLANEGRA, S ;
LEBEYEC, Y .
ANALYTICAL CHEMISTRY, 1985, 57 (11) :2035-2040
[3]   Post-source decay time-of-flight study of fragmentation mechanisms of protonated synthetic polymers under matrix-assisted laser desorption/ionization conditions [J].
Fournier, I ;
Marie, A ;
Lesage, D ;
Bolbach, G ;
Fournier, F ;
Tabet, JC .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (07) :696-704
[4]   Post-source decay in the analysis of polystyrene by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry [J].
Goldschmidt, RJ ;
Wetzel, SJ ;
Blair, WR ;
Guttman, CM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (12) :1095-1106
[5]   Metastable decay of negatively charged oligodeoxynucleotides analyzed with ultraviolet matrix-assisted laser desorption/ionization post-source decay and deuterium exchange [J].
Gross, J ;
Hillenkamp, F ;
Wan, KX ;
Gross, ML .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2001, 12 (02) :180-192
[6]   Optimization of matrix-assisted laser desorption/ionization time-of-flight collision-induced dissociation using poly(ethylene glycol) [J].
Hoteling, AJ ;
Kawaoka, K ;
Goodberlet, MC ;
Yu, WM ;
Owens, KG .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (14) :1671-1676
[7]   Generation of average mass values and end group information of polymers by means of a combination of matrix-assisted laser desorption ionization-mass spectrometry and liquid secondary ion tandem mass spectrometry [J].
Jackson, AT ;
Jennings, KR ;
Scrivens, JH .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (01) :76-85
[8]   Matrix-assisted laser desorption/ionization-collision induced dissociation of poly(styrene) [J].
Jackson, AT ;
Yates, HT ;
Scrivens, JH ;
Green, MR ;
Bateman, RH .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (04) :269-274
[9]  
JACKSON AT, 2002, P 50 ASMS C MASS SPE
[10]   Negative ion matrix-assisted laser desorption/ionization time-of-flight post-source decay calibration by using fibrinopeptide B [J].
Jai-nhuknan, J ;
Cassady, CJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (05) :540-544