Laboratory assessment of von Willebrand factor: Altered interpretation of laboratory data, and altered diagnosis of von Willebrand's disease

被引:29
作者
Favaloro, EJ
Mehrabani, PA
Koutts, J
机构
[1] Diagnostic Haemostasis Laboratory, Department of Haematology, Institute of Clinical Pathology and Medical Research (ICPMR), Western Sydney Area Health Service, Westmead, New South Wales
关键词
von Willebrand factor; von Willebrand's disease; laboratory assessment; normal ranges; reference ranges; diagnosis;
D O I
10.1177/107602969700300208
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Three laboratory assays for von Willebrand Factor (vWF), namely, (i) a standard ''antigen'' [antisera-enzyme-linked immunosorbent assay (ELISA)-based] (vWF:Ag), (ii) a standard ristocetin-dependent platelet agglutination procedure (vWF:RCof), and (iii) a newly developed ELISA-based functional vWF collagen binding assay (vWF:CBA), were coevaluated. We (a) assessed their ability to detect VWF under different assay conditions and Cb) reevaluated normal vWF reference ranges using citrated plasma from >200 normal individuals, The following effective normal reference ranges were derived: vWF-Ag (40-200%), vWF:CBA (50-400%), and vWF:RCof (45-200%). Based on other laboratory data, caution is indicated in the interpretation of ''borderline'' or ''equivocal'' test results (e.g., 35-55%), since these may derive from normal individuals or from vWD patients. Ln addition, our study shows that selection of different assay conditions, different test plasma dilutions, or different test sample processing methods can also lead to differences in the ''apparent'' levels of detected vWF. For example, using plasma from 100 normal individuals processed as ''test samples,'' we determined that higher sample dilutions tended to provide lower (dilution factor adjusted) assay results in the case of the vWF:Ag and vWF:CBA, and higher assay results in the case of the vWF:RCof, with greater differences noted in test samples containing higher levels of vWF. The explanation for these findings relate to the assay design. Thus, in the diagnostic laboratory, the standard vWF:Ag, vWF:CBA, and vWF:RCof assays procedures are designed to provide calibration curves that are ''upward linear'' in the (vWD) clinically important region of 0-50% of normal, with a plateau tending at higher VWF levels. Using these standard methodologies, and standard plasma dilutions, high-vWF level test samples will tend to fall on or near the plateau, and results will be unreliable, with a tendency to be exaggerated the higher the vWF. These findings have particular relevance to research studies measuring VWF in patients suffering various clinical conditions (e.g., thrombotic thrombocytopenic purpura, diabetes, renal failure) where higher than normal levels of VWF may be anticipated. In these cases, laboratory-derived vWF levels could be ''misrepresented'' if the study design did not take into account the need to revise the vWF testing procedure.
引用
收藏
页码:110 / 118
页数:9
相关论文
共 37 条
  • [11] FAVALORO EJ, 1995, AM J CLIN PATHOL, V104, P264
  • [12] DEVELOPMENT OF A SIMPLE COLLAGEN BASED ELISA ASSAY AIDS IN THE DIAGNOSIS OF, AND PERMITS SENSITIVE DISCRIMINATION BETWEEN TYPE-I AND TYPE-II, VONWILLEBRANDS DISEASE
    FAVALORO, EJ
    GRISPO, L
    EXNER, T
    KOUTTS, J
    [J]. BLOOD COAGULATION & FIBRINOLYSIS, 1991, 2 (02) : 285 - 291
  • [13] VON-WILLEBRANDS DISEASE - LABORATORY INVESTIGATION USING AN IMPROVED FUNCTIONAL ASSAY FOR VON-WILLEBRAND-FACTOR
    FAVALORO, EJ
    GRISPO, L
    DINALE, A
    BERNDT, M
    KOUTTS, J
    [J]. PATHOLOGY, 1993, 25 (02) : 152 - 158
  • [14] GIDDINGS JC, 1985, BLOOD COAGULATION HA, P135
  • [15] GIRMA JP, 1987, BLOOD, V70, P605
  • [16] GRALNICK HR, 1992, J LAB CLIN MED, V119, P444
  • [17] HANSEN JB, 1990, THROMB HAEMOSTASIS, V64, P385
  • [18] HEALY MJR, 1978, THROMB HAEMOSTASIS, V39, P504
  • [19] HERRMANN RP, 1977, BMJ JUN, P1601
  • [20] JANSSON JH, 1991, BRIT HEART J, V66, P351