CdZnTe pixel array detectors and implications for producing large volume gamma-ray spectrometers

被引:16
作者
Brunett, BA [1 ]
Van Scyoc, JM
James, RB
Schlesinger, TE
机构
[1] Sandia Natl Labs, Livermore, CA 94550 USA
[2] Carnegie Mellon Univ, Pittsburgh, PA 15213 USA
关键词
D O I
10.1063/1.371309
中图分类号
O59 [应用物理学];
学科分类号
摘要
In this article we show that the behavior of new devices fabricated from horizontal Bridgman CdZnTe reported recently can be explained by the same conventional electrostatics arguments used to analyze detectors made from high pressure Bridgman material, and no qualitative differences in the material or contacts are necessary to explain the behavior of these new devices. Our work is an extension of the results obtained with a similar device geometry fabricated on high pressure Bridgman material. In addition we discuss the possibility of extending the design concepts learned here to fabricate large volume spectrometers based on a pixel array design. (C) 1999 American Institute of Physics. [S0021-8979(99)05419-5].
引用
收藏
页码:3926 / 3933
页数:8
相关论文
共 10 条
[1]   Signals induced in semiconductor gamma-ray imaging detectors [J].
Eskin, JD ;
Barrett, HH ;
Barber, HB .
JOURNAL OF APPLIED PHYSICS, 1999, 85 (02) :647-659
[2]   SIGNAL-PROCESSING FOR SEMICONDUCTOR-DETECTORS [J].
GOULDING, FS ;
LANDIS, DA .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1982, 29 (03) :1125-1141
[3]   Position-sensitive single carrier CdZnTe detectors [J].
He, Z ;
Knoll, GF ;
Wehe, DK ;
Miyamoto, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 388 (1-2) :180-185
[4]   For the mechanism of the photoelectric primary current in insulating crystals. [J].
Hecht, Karl .
ZEITSCHRIFT FUR PHYSIK, 1932, 77 (3-4) :235-245
[5]   The role of contacts in semiconductor gamma radiation detectors [J].
Lachish, U .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 403 (2-3) :417-424
[6]   LOW-NOISE TECHNIQUES IN DETECTORS [J].
RADEKA, V .
ANNUAL REVIEW OF NUCLEAR AND PARTICLE SCIENCE, 1988, 38 :217-277
[7]  
SCHLESINGER TE, IN PRESS J ELECT MAT
[8]   Spectroscopy with CdZnTe γ- and X-ray detectors by modifying the electron trapping to compensate for incomplete charge collection caused by large hole trapping [J].
Shor, A ;
Eisen, Y ;
Mardor, I .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 426 (2-3) :491-496
[9]   Current issues of high-pressure Bridgman growth of semi-insulating CdZnTe [J].
Szeles, C ;
Eissler, EE .
SEMICONDUCTORS FOR ROOM-TEMPERATURE RADIATION DETECTOR APPLICATIONS II, 1997, 487 :3-12
[10]  
TSOULFANIDIS N, 1995, MEASUREMENT DETECTIO, P347