General methods for optimized design and calibration of Mueller polarimeters

被引:67
作者
De Martino, A [1 ]
Garcia-Caurel, E [1 ]
Laude, B [1 ]
Drévillon, B [1 ]
机构
[1] Ecole Polytech, CNRS, UMR 7647, Phys Interfaces & Couches Minces Lab, F-91128 Palaiseau, France
关键词
polarimetry; Mueller matrix; calibration; imaging;
D O I
10.1016/j.tsf.2003.12.052
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A Mueller polarimeter always comprises a polarization state generator (PSG) and a polarization state analyzer (PSA), whose configurations determine the modulation and analysis matrices W and A, involved in the linear relationship between the raw measurement matrix B and the Mueller matrix M of the sample under study. At constant noise in the raw data B, the noise in M is minimized when the condition numbers of both A and W are optimized [E. Compain et al., Rev. Sci. Instrum. 68 (1997) 2671; S. Tyo, Appl. Opt. 41 (2002) 619]. This result provides a quite general criterion for the optimization of instrument design. Typically, this optimization leads to PSG and PSA configurations, which may be difficult to calibrate accurately by usual procedures. This key issue is easily solved by the quite general eigenvalue calibration method [E. Compain et al., Appl. Opt. OT 38 (1999) 3490]. The usefulness of this approach for the development of innovative polarimeters is illustrated with two instruments. One of these comprises a photoelastic modulator and a division-of-amplitude prism, and features a high dynamical range over a broad spectrum, while the other, based on liquid crystal variable retarders, is better suited for imaging applications in the visible and the near infrared. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:112 / 119
页数:8
相关论文
共 24 条
[1]  
AZZAM RMA, 1977, OPT LETT, V2, P181
[2]  
AZZAM RMA, 1986, ELLIPSOMETRY POLARIZ
[3]  
Born M., 1959, PRINCIPLES OPTICS
[4]   Polarization errors associated with zero-order achromatic quarter-wave plates in the whole visible spectral range [J].
Boulbry, B ;
Bousquet, B ;
Le Jeune, B ;
Guern, Y ;
Lotrian, J .
OPTICS EXPRESS, 2001, 9 (05) :225-235
[5]   Double-pass imaging polarimetry in the human eye [J].
Bueno, JM ;
Artal, P .
OPTICS LETTERS, 1999, 24 (01) :64-66
[6]  
Collett E., 1993, POLARIZED LIGHT FUND
[7]   Dual rotating-compensator multichannel ellipsometer: instrument design for real-time Mueller matrix spectroscopy of surfaces and films [J].
Collins, RW ;
Koh, J .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1999, 16 (08) :1997-2006
[8]   Broadband division-of-amplitude polarimeter based on uncoated prisms [J].
Compain, E ;
Drevillon, B .
APPLIED OPTICS, 1998, 37 (25) :5938-5944
[9]   General and self-consistent method for the calibration of polarization modulators, polarimeters, and Mueller-matrix ellipsometers [J].
Compain, E ;
Poirier, S ;
Drevillon, B .
APPLIED OPTICS, 1999, 38 (16) :3490-3502
[10]   Complete high-frequency measurement of Mueller matrices based on a new coupled-phase modulator [J].
Compain, E ;
Drevillon, B .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (07) :2671-2680