Accuracy of EEG dipole source localization using implanted sources in the human brain

被引:67
作者
Krings, T
Chiappa, KH [1 ]
Cuffin, BN
Cochius, JI
Connolly, S
Cosgrove, GR
机构
[1] Massachusetts Gen Hosp, Serv Neurol, Clin Neurophysiol Lab, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Epilepsy Ctr, Boston, MA 02114 USA
[3] Massachusetts Gen Hosp, MIT, Francis Bitter Natl Magnet Lab, Boston, MA 02114 USA
[4] Massachusetts Gen Hosp, Neurosurg Serv, Boston, MA 02114 USA
关键词
artificial; dipole; human; source; localization;
D O I
10.1016/S0013-4694(98)00106-0
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objectives: The location of electrical sources in the brain can be estimated by calculating inverse solutions in which the location, amplitude and orientation of the electrical sources are fitted to the scalp EEG. To assess localization accuracy of the moving dipole inverse solution algorithm (ISA), we studied two patients who had depth electrodes implanted for presurgical planning of epilepsy surgery. Methods: Artificial dipoles were created by connecting a single sine wave pulse generator to different pairs of electrodes in multiple orientations and depths. Surface EEG recordings of the resulting pulses were evaluated with the ISA using a 4 shell spherical head model and plotted on the subjects' MRI. Dipole localization errors were evaluated with respect to the number of averaged pulses, different electrode montages and different dipole locations and orientations. Results: Dipoles located at 40-57 mm from the scalp surface had localization errors that were greater than those located at 62-85 mm. Localization accuracy improved with increasing numbers of pulses and recording electrodes. Results with a standard 10-20 array of 21 electrodes showed an average localization error of 17 mm, whereas 41 electrodes improved this to 13 mm. Mean angular errors were 31 and 30 degrees, respectively. Conclusions: The ISA was able to differentiate between tangential and radial dipoles. We conclude that our implementation of the ISA is a useful and sound method for localizing electrical activity in the brain. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:106 / 114
页数:9
相关论文
共 34 条
  • [1] INTRACEREBRAL PROPAGATION OF INTERICTAL ACTIVITY IN PARTIAL EPILEPSY - IMPLICATIONS FOR SOURCE LOCALIZATION
    ALARCON, G
    GUY, CN
    BINNIE, CD
    WALKER, SR
    ELWES, RDC
    POLKEY, CE
    [J]. JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1994, 57 (04) : 435 - 449
  • [2] NEUROMAGNETIC EVIDENCE OF SPATIALLY DISTRIBUTED SOURCES UNDERLYING EPILEPTIFORM SPIKES IN THE HUMAN-BRAIN
    BARTH, DS
    SUTHERLING, W
    ENGLE, J
    BEATTY, J
    [J]. SCIENCE, 1984, 223 (4633) : 293 - 296
  • [3] BUCHNER H, 1991, EEG-EMG-Z ELEK ELEKT, V22, P62
  • [4] MEG VERSUS EEG LOCALIZATION TEST USING IMPLANTED SOURCES IN THE HUMAN BRAIN
    COHEN, D
    CUFFIN, BN
    YUNOKUCHI, K
    MANIEWSKI, R
    PURCELL, C
    COSGROVE, GR
    IVES, J
    KENNEDY, JG
    SCHOMER, DL
    [J]. ANNALS OF NEUROLOGY, 1990, 28 (06) : 811 - 817
  • [6] CUFFIN BN, 1979, ELECTROEN CLIN NEURO, V47, P132, DOI 10.1016/0013-4694(79)90215-3
  • [7] EEG localization accuracy improvements using realistically shaped head models
    Cuffin, BN
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (03) : 299 - 303
  • [8] TESTS OF EEG LOCALIZATION ACCURACY USING IMPLANTED SOURCES IN THE HUMAN BRAIN
    CUFFIN, BN
    COHEN, D
    YUNOKUCHI, K
    MANIEWSKI, R
    PURCELL, C
    COSGROVE, GR
    IVES, J
    KENNEDY, J
    SCHOMER, D
    [J]. ANNALS OF NEUROLOGY, 1991, 29 (02) : 132 - 138
  • [10] SPIKE VOLTAGE TOPOGRAPHY IDENTIFIES 2 TYPES OF FRONTOTEMPORAL EPILEPTIC FOCI
    EBERSOLE, JS
    WADE, PB
    [J]. NEUROLOGY, 1991, 41 (09) : 1425 - 1433