Permanent modification in electrothermal atomic absorption spectrometry - advances, anticipations and reality

被引:107
作者
Tsalev, DL
Slaveykova, VI
Lampugnani, L
D'Ulivo, A
Georgieva, R
机构
[1] Univ Sofia, Fac Chem, BU-1126 Sofia, Bulgaria
[2] CNR, Ist Chim Analit Strumentale, Area Ric Pisa, I-56010 Pisa, Italy
[3] Natl Ctr Hyg Med Ecol & Nutr, Sofia 1431, Bulgaria
关键词
electrothermal atomic absorption spectrometry; chemical modifier; carbide-modified graphite tubes; high-melting carbides; noble metals;
D O I
10.1016/S0584-8547(00)00194-4
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Permanent modification is an important recent development in chemical modification techniques which is promising in view of increasing sample throughput with 'fast' programs, reducing reagent blanks, preliminary elimination of unwanted modifier components, compatibility with on-line and in situ enrichment, etc. An overview of this approach based on the authors' recent research and scarce literature data is given, revealing both success and failure in studies with permanently modified surfaces (carbides, non-volatile noble metals, noble metals on carbide coatings, etc.), as demonstrated in examples of direct electrothermal atomic absorption spectrometric (ETAAS) applications to biological and environmental matrices and vapor generation (VG)-ETAAS coupling with in-atomizer trapping of hydrides and other analyte vapors. Permanent modifiers exhibit certain drawbacks and limitations such as: poorly reproducible treatment technologies - eventually resulting in poor tube-to-tube repeatability and double or multiple peaks; impaired efficiency compared with modifier addition to each sample aliquot; relatively short lifetimes; limitations imposed on temperature programs, the pyrolysis, atomization and cleaning temperatures being set somewhat lower to avoid excessive loss of modifier; applicability to relatively simple sample solutions rather than to high-salt matrices and acidic digests; side effects of overstabilization, etc. The most important niches of application appear to be the utilization of permanently modified surfaces in coupled VG-ETAAS techniques, analysis of organic solvents and extracts, concentrates and fractions obtained after enrichment and/or speciation separations and direct ETAAS determinations of highly volatile analytes in relatively simple sample matrices. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:473 / 490
页数:18
相关论文
共 79 条
[1]   Selenium determination using ethylation and on-line trapping/detection by graphite furnace atomic absorption spectrometry [J].
Allabashi, R ;
Rendl, J ;
Grasserbauer, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (06) :723-725
[2]  
BAO C, 1991, GUANGPUYUE YU GUANGP, V11, P56
[3]   Selective medium reactions for the 'arsenic(III)', 'arsenic(V)', dimethylarsonic acid and monomethylarsonic acid determination in waters by hydride generation on-line electrothermal atomic absorption spectrometry with in situ preconcentration on Zr-coated graphite tubes [J].
Bermejo-Barrera, P ;
Moreda-Piñeiro, J ;
Moreda-Piñeiro, A ;
Bermejo-Barrera, A .
ANALYTICA CHIMICA ACTA, 1998, 374 (2-3) :231-240
[4]   Direct trace determination of lead in estuarine water using in situ preconcentration of lead hydride on Ir, Zr and W-coated graphite tubes [J].
Bermejo-Barrera, P ;
Moreda-Piñeiro, J ;
Moreda-Piñeiro, A ;
Bermejo-Barrera, A .
ANALYTICA CHIMICA ACTA, 1998, 368 (03) :281-289
[5]   Use of flow injection cold vapour generation and preconcentration on coated graphite tubes for the determination of mercury in polluted seawaters by electrothermal atomic absorption spectrometry [J].
BermejoBarrera, P ;
MoredaPineiro, J ;
MoredaPineiro, A ;
BermejoBarrera, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (03) :317-321
[6]   Use of flow injection cold vapour generation and preconcentration on coated graphite tubes for the determination of cadmium in sea-water by electrothermal atomic absorption spectrometry [J].
BermejoBarrera, P ;
MoredaPineiro, J ;
MoredaPineiro, A ;
BermejoBarrera, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (11) :1081-1086
[7]   APPLICATION OF PALLADIUM-PLATING AND RHODIUM-PLATING OF THE GRAPHITE-FURNACE IN ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BULSKA, E ;
JEDRAL, W .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (01) :49-53
[8]   Optimization of electrochemical deposition of noble metals for permanent modification in graphite furnace atomic absorption spectrometry [J].
Bulska, E ;
Liebert-Ilkowska, K ;
Hulanicki, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (6-8) :1057-1062
[9]   Noble metals as permanent modifiers for the determination of mercury by electrothermal atomic absorption spectrometry [J].
Bulska, E ;
Kandler, W ;
Hulanicki, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (9-10) :1263-1270
[10]   Determination of selenium species in seawater by flow injection hydride generation in situ trapping followed by electrothermal atomic absorption spectrometry [J].
Cabon, JY ;
Erler, W .
ANALYST, 1998, 123 (07) :1565-1569