A simple model for examining issues in radiotherapy optimization

被引:25
作者
Shepard, DM [1 ]
Olivera, G [1 ]
Angelos, L [1 ]
Sauer, O [1 ]
Reckwerdt, P [1 ]
Mackie, TR [1 ]
机构
[1] Univ Wisconsin, Dept Phys Med, Madison, WI 53706 USA
关键词
D O I
10.1118/1.598615
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Convolution/superposition software has been used to produce a library of photon pencil beam dose matrices. This library of pencil beams is designed to serve as a tool for both education and investigation in the held of radiotherapy optimization. The elegance of this pencil beam model stems from its cylindrical symmetry. Because of the symmetry,the dose distribution for a pencil beam from any arbitrary angle can be determined through a simple rotation of a pre-computed dose matrix. Rapid dose calculations can thus be performed while maintaining the accuracy df a convolution/superposition based dose computation. The pencil beam data sets have been made publicly available. It is hoped that the data sets will facilitate a comparison of a variety of optimization and delivery approaches. This paper will present a number of studies designed to demonstrate the usefulness of the pencil beam data sets. These studies include an examination of the extent to which a treatment plan can be improved through either an increase in the number of beam angles and/or a decrease in the collimator size. A few insights into,the significance of heterogeneity corrections for treatment planning for intensity modulated radiotherapy will also be presented. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)02007-6].
引用
收藏
页码:1212 / 1221
页数:10
相关论文
共 32 条
[11]  
GRACE A, 1995, OPTIMIZATION TOOLBOX
[12]   A continuous penalty function method for inverse treatment planning [J].
Hristov, DH ;
Fallone, BG .
MEDICAL PHYSICS, 1998, 25 (02) :208-223
[13]   DYNAMIC WEDGE FIELD TECHNIQUES THROUGH COMPUTER-CONTROLLED COLLIMATOR MOTION AND DOSE DELIVERY [J].
LEAVITT, DD ;
MARTIN, M ;
MOELLER, JH ;
LEE, WL .
MEDICAL PHYSICS, 1990, 17 (01) :87-91
[14]  
LEIBEL S, 1993, UNPUB 3D RAD TREATM
[15]  
LLACER J, 1998, UNPUB AM ASS PHYS ME
[16]   LETTER IN RESPONSE TO OPTIMIZATION OF RADIATION-THERAPY AND THE DEVELOPMENT OF MULTILEAF COLLIMATION BY BRAHME,ANDERS [J].
MACKIE, R ;
DEASY, J ;
HOLMES, T ;
FOWLER, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (03) :784-785
[17]   A CONVOLUTION METHOD OF CALCULATING DOSE FOR 15-MV X-RAYS [J].
MACKIE, TR ;
SCRIMGER, JW ;
BATTISTA, JJ .
MEDICAL PHYSICS, 1985, 12 (02) :188-196
[18]   TOMOTHERAPY - A NEW CONCEPT FOR THE DELIVERY OF DYNAMIC CONFORMAL RADIOTHERAPY [J].
MACKIE, TR ;
HOLMES, T ;
SWERDLOFF, S ;
RECKWERDT, P ;
DEASY, JO ;
YANG, J ;
PALIWAL, B ;
KINSELLA, T .
MEDICAL PHYSICS, 1993, 20 (06) :1709-1719
[19]  
MACKIE TR, 1993, UNPUB 3D RAD TREATM
[20]  
Mohan, 1995, Semin Radiat Oncol, V5, P86, DOI 10.1016/S1053-4296(95)80003-4