Rapid high-resolution T1 mapping by variable flip angles:: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity

被引:290
作者
Cheng, HLM
Wright, GA
机构
[1] Hosp Sick Children, Dept Diagnost Imaging, Toronto, ON M5G 1X8, Canada
[2] Hosp Sick Children, Res Inst, Toronto, ON M5G 1X8, Canada
[3] Hosp Sick Children, Dept Med Imaging, Toronto, ON, Canada
[4] Sunnybrook & Womens Coll, Hlth Sci Ctr, Toronto, ON, Canada
[5] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
关键词
T-1; mapping; fast volumetric imaging; high-field MRI; quantitative MRI;
D O I
10.1002/mrm.20791
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rapid 3D mapping of T-1 relaxation times is valuable in diverse clinical applications. Recently, the variable flip angle (VFA) spoiled gradient recalled echo approach was shown to be a practical alternative to conventional methods, providing better precision and speed. However, the method is known to be sensitive to transmit field (B-1(+)) inhomogeneity and can result in significant systematic errors in T-1 estimates, especially at high field strengths. The main challenge is to improve the accuracy of the VFA approach without sacrificing speed. In this article, the VFA method was optimized for both accuracy and precision by considering the influence of imperfect transmit fields, noise bias, and selection of flip angles. An analytic solution was developed for systematic B-1(+)-induced T-1 errors and allows simple correction of T-1 measurements acquired with any imaging parameters. A noise threshold was also identified and provided a guideline for avoiding T-1 biases. Finally, it was shown that three flip angles were the most efficient for maintaining accuracy and high precision over large ranges of T-1. A rapid B-1(+) mapping sequence was employed in all phantom experiments and high-field in vivo brain scans. Experimental results confirmed the theory and validated the accuracy of the proposed method.
引用
收藏
页码:566 / 574
页数:9
相关论文
共 27 条
[1]  
BEVINGTON PR, 1969, DATA REDUCTION ERROR, P99
[2]  
Brookes JA, 1999, JMRI-J MAGN RESON IM, V9, P163, DOI 10.1002/(SICI)1522-2586(199902)9:2<163::AID-JMRI3>3.0.CO
[3]  
2-L
[4]   OPTIMAL DETERMINATION OF RELAXATION-TIMES OF FOURIER-TRANSFORM NUCLEAR MAGNETIC-RESONANCE - DETERMINATION OF SPIN-LATTICE RELAXATION-TIMES IN CHEMICALLY POLARIZED SPECIES [J].
CHRISTENSEN, KA ;
GRANT, DM ;
SCHULMAN, EM ;
WALLING, C .
JOURNAL OF PHYSICAL CHEMISTRY, 1974, 78 (19) :1971-1977
[5]   A COMPARISON OF ONE-SHOT AND RECOVERY METHODS IN T1-IMAGING [J].
CRAWLEY, AP ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1988, 7 (01) :23-34
[6]   High-resolution T1 and T2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2 [J].
Deoni, SCL ;
Peters, TM ;
Rutt, BK .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (01) :237-241
[7]   Determination of optimal angles for variable nutation proton magnetic spin-lattice, T1, and spin-spin, T2, relaxation times measurement [J].
Deoni, SCL ;
Peters, TM ;
Rutt, BK .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) :194-199
[8]   Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state [J].
Deoni, SCL ;
Rutt, BK ;
Peters, TM .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (03) :515-526
[9]   Comparison of longitudinal metabolite relaxation times in different regions of the human brain at 1.5 and 3 Tesla [J].
Ethofer, T ;
Mader, I ;
Seeger, U ;
Helms, G ;
Erb, M ;
Grodd, W ;
Ludolph, A ;
Klose, U .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (06) :1296-1301
[10]   SNAPSHOT FLASH MRI - APPLICATIONS TO T1, T2, AND CHEMICAL-SHIFT IMAGING [J].
HAASE, A .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (01) :77-89