Cancer incidence and causes of death among total hip replacement patients: a review based on Nordic cohorts with a special emphasis on metal-on-metal bearings

被引:74
作者
Visuri, TI
Pukkala, E
Pulkkinen, P
Paavolainen, P
机构
[1] Cent Mil Hosp, Res Inst Mil Med, Espoo, Finland
[2] Cent Mil Hosp, Dept Surg, Espoo, Finland
[3] Finnish Canc Registry, Inst Stat & Epidemiol Canc Res, FIN-00170 Helsinki, Finland
[4] Univ Helsinki, Dept Publ Hlth, FIN-00014 Helsinki, Finland
[5] Invalid Fdn, Hosp ORTON, Helsinki, Finland
关键词
total hip arthroplasty; metal-on-metal implants; metal-on-polyethylene implants; cancer incidence; mortality; causes of death;
D O I
10.1243/095441105X63282
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
All patients with total hip arthroplasty (THA) are exposed to soluble or particulate forms of Co and Cr. Adverse effects of these wear products are not known. Data from Nordic registries is used to estimate adverse effects on a large scale, based mostly on metal-on-polyethylene bearings. Cancer incidence was in line with the general population when the patients were operated on for all indications and significantly decreased when the indication was primary osteoarthritis. Stomach cancer and colorectal cancers were significantly reduced and prostate cancer and skin melanoma significantly increased. There was no significant excess of cancer in target organs, i.e. liver, kidney, or haematopoietic cancers. THA patients had reduced mortality and extended life expectancy compared with standard Nordic populations. All-site cancer incidence of the first-generation metal-on-metal McKee-Farrar patients operated on for primary osteoarthritis was in line with the general population after follow-up for up to 28 years. General mortality of these patients was also reduced and they also had an extended life expectancy. Temporary increases in haematopoietic cancers at different follow-up periods were seen in some cohorts. This malignancy deserves a special record linkage monitoring while large numbers of young patients are provided with the second generation of metal-on-metal prostheses.
引用
收藏
页码:399 / 407
页数:9
相关论文
共 76 条
[1]
Metal-on-metal hybrid surface arthroplasty:: Two to six-year follow-up study [J].
Amstutz, HC ;
Beaulé, PE ;
Dorey, FJ ;
Le Duff, MJ ;
Campbell, PA ;
Gruen, TA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (01) :28-39
[2]
Metal-on-metal bearing in hip prosthesis generates 100-fold less wear debris than metal-on-polyethylene [J].
Anissian, HL ;
Stark, A ;
Gustafson, A ;
Good, V ;
Clarke, IC .
ACTA ORTHOPAEDICA SCANDINAVICA, 1999, 70 (06) :578-582
[3]
Archibeck MJ, 2000, CLIN ORTHOP RELAT R, P12
[4]
Occult sarcoma of the femoral head in patients undergoing total hip arthroplasty - A report of two cases [J].
Billings, SD ;
Wurtz, LD ;
Tejada, E ;
Henley, JD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (11) :1536-1539
[5]
INVOLVEMENT OF INFLAMMATORY MEDIATORS IN MACROPHAGE ANTITUMOR-ACTIVITY [J].
BONTA, IL ;
BENEFRAIM, S .
JOURNAL OF LEUKOCYTE BIOLOGY, 1993, 54 (06) :613-626
[6]
RISK ASSESSMENT OF CARCINOGENESIS AT IMPLANTATION SITES [J].
BRAND, KG ;
BRAND, I .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1980, 66 (04) :591-594
[7]
Serum cobalt levels after metal-on-metal total hip arthroplasty [J].
Brodner, W ;
Bitzan, P ;
Meisinger, V ;
Kaider, A ;
Gottsauner-Wolf, F ;
Kotz, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (11) :2168-2173
[8]
Autopsy analysis thirty years after metal-on-metal total hip replacement - A case report [J].
Campbell, P ;
Urban, RM ;
Catelas, I ;
Skipor, AK ;
Schmalzried, TP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (11) :2218-2222
[9]
WIDESPREAD DISSEMINATION OF METAL DEBRIS FROM IMPLANTS [J].
CASE, CP ;
LANGKAMER, VG ;
JAMES, C ;
PALMER, MR ;
KEMP, AJ ;
HEAP, PF ;
SOLOMON, L .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (05) :701-712
[10]
CASE CP, 1996, CLIN ORTHOP S, V329, P269