Evaluation of an improved technique for automated center lumen line definition in cardiovascular image data

被引:4
作者
van Andel, HAFG
Meijering, E
van der Lugt, A
Vrooman, HA
de Monyé, C
Stokking, R
机构
[1] Univ Med Ctr Rotterdam, Erasmus MC, Dept Med Informat, NL-3015 GE Rotterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Phys Med, NL-1105 AZ Amsterdam, Netherlands
关键词
arteries; computed tomography (CT); angiography; computers; diagnostic aid; diagnostic radiology; observer performance; images; analysis;
D O I
10.1007/s00330-005-2854-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the study was to evaluate a new method for automated definition of a center lumen line in vessels in cardiovascular image data. This method, called VAMPIRE, is based on improved detection of vessel-like structures. A multiobserver evaluation study was conducted involving 40 tracings in clinical CTA data of carotid arteries to compare VAMPIRE with an established technique. This comparison showed that VAMPIRE yields considerably more successful tracings and improved handling of stenosis, calcifications, multiple vessels, and nearby bone structures. We conclude that VAMPIRE is highly suitable for automated definition of center lumen lines in vessels in cardiovascular image data.
引用
收藏
页码:391 / 398
页数:8
相关论文
共 30 条
[1]   Initialization, noise, singularities, and scale in height ridge traversal for tubular object centerline extraction [J].
Aylward, SR ;
Bullitt, E .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (02) :61-75
[2]  
Cormen T. H., 2001, Introduction to Algorithms, V2nd
[3]   An ultra-fast user-steered image segmentation paradigm: Live wire on the fly [J].
Falcao, AX ;
Udupa, JK ;
Miyazawa, FK .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (01) :55-62
[4]   Model-based quantitation of 3-D magnetic resonance angiographic images [J].
Frangi, AF ;
Niessen, WJ ;
Hoogeveen, RM ;
van Walsum, T ;
Viergever, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (10) :946-956
[5]  
Frangi AF, 1998, LECT NOTES COMPUT SC, V1496, P130, DOI 10.1007/BFb0056195
[6]   Evaluation of center-line extraction algorithms in quantitative coronary angiography [J].
Greenspan, H ;
Laifenfeld, M ;
Einav, S ;
Barnea, O .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (09) :928-941
[7]   Model-based morphological segmentation and labeling of coronary angiograms [J].
Haris, K ;
Efstratiadis, SN ;
Maglaveras, N ;
Pappas, C ;
Gourassas, J ;
Louridas, G .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (10) :1003-1015
[8]   Automatic detection of calcifications in the aorta from CT scans of the abdomen - 3D computer-aided diagnosis [J].
Isgum, I ;
van Ginneken, B ;
Olree, M .
ACADEMIC RADIOLOGY, 2004, 11 (03) :247-257
[9]   Design of steerable filters for feature detection using Canny-like criteria [J].
Jacob, M ;
Unser, M .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2004, 26 (08) :1007-1019
[10]   CURVES: Curve evolution for vessel segmentation [J].
Lorigo, LM ;
Faugeras, OD ;
Grimson, WEL ;
Keriven, R ;
Kikinis, R ;
Nabavi, A ;
Westin, CF .
MEDICAL IMAGE ANALYSIS, 2001, 5 (03) :195-206