Model-based quantitation of 3-D magnetic resonance angiographic images

被引:283
作者
Frangi, AF [1 ]
Niessen, WJ [1 ]
Hoogeveen, RM [1 ]
van Walsum, T [1 ]
Viergever, MA [1 ]
机构
[1] Univ Utrecht, Med Ctr, Image Sci Inst, NL-3584 CX Utrecht, Netherlands
关键词
magnetic resonance angiography; model-based image analysis; quantification; stenosis grading;
D O I
10.1109/42.811279
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Quantification of the degree of stenosis or vessel dimensions are important for diagnosis of vascular diseases and planning vascular interventions, Although diagnosis from three-dimensional (3-D) magnetic resonance angiograms (MRA's) is mainly performed on two-dimensional (2-D) maximum intensity projections, automated quantification of vascular segments directly from the 3-D dataset is desirable to provide accurate and objective measurements of the 3-D anatomy. A model-based method for quantitative 3-D MRA is proposed. Linear vessel segments are modeled with a central vessel axis curve coupled to a vessel wall surface. A novel image feature to guide the deformation of the central vessel axis is introduced. Subsequently, concepts of deformable models are combined with knowledge of the physics of the acquisition technique to accurately segment the vessel wall and compute the vessel diameter and other geometrical properties. The method is illustrated and validated on a carotid bifurcation phantom, with ground truth and medical experts as comparisons, Also, results on 3-D time-of-flight (TOF) MRA images of the carotids are shown, The approach is a promising technique to assess several geometrical vascular parameters directly on the source 3-D images, providing an objective mechanism for stenosis grading.
引用
收藏
页码:946 / 956
页数:11
相关论文
共 48 条
  • [1] MEASUREMENT OF INTERNAL CAROTID-ARTERY STENOSIS FROM SOURCE MR ANGIOGRAMS
    ANDERSON, CM
    LEE, RE
    LEVIN, DL
    ALONSO, SD
    SALONER, D
    [J]. RADIOLOGY, 1994, 193 (01) : 219 - 226
  • [2] ARTIFACTS IN MAXIMUM-INTENSITY-PROJECTION DISPLAY OF MR ANGIOGRAMS
    ANDERSON, CM
    SALONER, D
    TSURUDA, JS
    SHAPEERO, LG
    LEE, RE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (03) : 623 - 629
  • [3] Intensity ridge and widths for tubular object segmentation and description
    Aylward, S
    Pizer, S
    Bullitt, E
    Eberly, D
    [J]. PROCEEDINGS OF THE IEEE WORKSHOP ON MATHEMATICAL METHODS IN BIOMEDICAL IMAGE ANALYSIS, 1996, : 131 - 138
  • [5] BLATTER DD, 1993, AM J ROENTGENOL, V161, P1269, DOI 10.2214/ajr.161.6.8249741
  • [6] AN ALGORITHM FOR MR-ANGIOGRAPHY IMAGE-ENHANCEMENT
    CHEN, HG
    HALE, J
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (04) : 534 - 540
  • [7] VOLUME RENDERING AND CONNECTIVITY ALGORITHMS FOR MR ANGIOGRAPHY
    CLINE, HE
    DUMOULIN, CL
    LORENSEN, WE
    SOUZA, SP
    ADAMS, WJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) : 384 - 394
  • [8] PROSPECTIVE EVALUATION OF EXTRACRANIAL CAROTID STENOSIS - NIR ANGIOGRAPHY WITH MAXIMUM-INTENSITY PROJECTIONS AND MULTIPLANAR REFORMATION COMPARED WITH CONVENTIONAL ANGIOGRAPHY
    DEMARCO, JK
    NESBIT, GM
    WESBEY, GE
    RICHARDSON, D
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (05) : 1205 - 1212
  • [9] Vessel enhancement filtering in three-dimensional MR angiograms using long-range signal correlation
    Du, YP
    Parker, DL
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (02): : 447 - 450
  • [10] REDUCTION OF PARTIAL-VOLUME ARTIFACTS WITH ZERO-FILLED INTERPOLATION IN 3-DIMENSIONAL MR-ANGIOGRAPHY
    DU, YPP
    PARKER, DL
    DAVIS, WL
    CAO, G
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05): : 733 - 741