MEASUREMENT OF INTERNAL CAROTID-ARTERY STENOSIS FROM SOURCE MR ANGIOGRAMS

被引:53
作者
ANDERSON, CM
LEE, RE
LEVIN, DL
ALONSO, SD
SALONER, D
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT RADIOL,SAN FRANCISCO,CA 94143
[2] HOSP UNIV SAN CARLOS,DEPT RADIOL,MADRID,SPAIN
关键词
CAROTID ARTERIES; ANGIOGRAPHY; STENOSIS OR OBSTRUCTION; MAGNETIC RESONANCE (MR); COMPARATIVE STUDIES; VASCULAR STUDIES;
D O I
10.1148/radiology.193.1.8090894
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine whether interpretation of internal carotid artery (ICA) stenosis from source partitions is more accurate than interpretation from maximum-intensity projections (MIPs) from three-dimensional (3D) time-of-flight (TOF) magnetic resonance (MR) angiography. MATERIALS AND METHODS: The percentage of diameter ICA stenosis was measured on source images and MIPs from sagittal (n = 150) and transverse (n = 140) 3D TOF MR angiography. Measurements were compared with those from conventional angiography. RESULTS: Sensitivity and specificity for distinguishing 70%-99% stenosis were 96% and 78%, respectively, for sagittal MIPs, 88% and 90% for sagittal source images, 92% and 86% for transverse MIPs, and 92% and 95% for transverse source images. Areas under the receiver operating characteristic curves statistically significantly increased (P < .05) with interpretation from source images. Complete loss of intravascular signal was not encountered on source partitions except within a greater than 85% stenosis. CONCLUSION: Interpretation of source partitions rather than MIPs reduces the tendency for overestimation of stenosis with MR angiography and improves the specificity for discriminating 70%-99% stenosis.
引用
收藏
页码:219 / 226
页数:8
相关论文
共 25 条
  • [1] ANDERSON CM, 1992, AM J NEURORADIOL, V13, P989
  • [2] ARTIFACTS IN MAXIMUM-INTENSITY-PROJECTION DISPLAY OF MR ANGIOGRAMS
    ANDERSON, CM
    SALONER, D
    TSURUDA, JS
    SHAPEERO, LG
    LEE, RE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (03) : 623 - 629
  • [3] Baker J D, 1988, J Vasc Surg, V8, P721
  • [4] CAROTID ENDARTERECTOMY AND THE MEASUREMENT OF STENOSIS
    BARNETT, HJM
    WARLOW, CP
    [J]. STROKE, 1993, 24 (09) : 1281 - 1284
  • [5] ROLE OF DUPLEX SCANNING IN THE SELECTION OF PATIENTS FOR CAROTID ENDARTERECTOMY
    FARMILO, RW
    SCOTT, DJA
    COLE, SEA
    JEANS, WD
    HORROCKS, M
    [J]. BRITISH JOURNAL OF SURGERY, 1990, 77 (04) : 388 - 390
  • [6] HOW TO MEASURE CAROTID STENOSIS
    FOX, AJ
    [J]. RADIOLOGY, 1993, 186 (02) : 316 - 318
  • [7] A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES
    HANLEY, JA
    MCNEIL, BJ
    [J]. RADIOLOGY, 1983, 148 (03) : 839 - 843
  • [8] CAROTID-ARTERY STENOSIS - CLINICAL EFFICACY OF 2-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY
    HEISERMAN, JE
    DRAYER, BP
    FRAM, EK
    KELLER, PJ
    BIRD, CR
    HODAK, JA
    FLOM, RA
    [J]. RADIOLOGY, 1992, 182 (03) : 761 - 768
  • [9] CAROTID-ARTERY - PROSPECTIVE BLINDED COMPARISON OF 2-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY WITH CONVENTIONAL ANGIOGRAPHY AND DUPLEX US
    HUSTON, J
    LEWIS, BD
    WIEBERS, DO
    MEYER, FB
    RIEDERER, SJ
    WEAVER, AL
    [J]. RADIOLOGY, 1993, 186 (02) : 339 - 344
  • [10] 3DFT MR-ANGIOGRAPHY OF THE CAROTID BIFURCATION - POTENTIAL AND LIMITATIONS AS A SCREENING EXAMINATION
    MASARYK, AM
    ROSS, JS
    DICELLO, MC
    MODIC, MT
    PARANANDI, L
    MASARYK, TJ
    [J]. RADIOLOGY, 1991, 179 (03) : 797 - 804