Vessel enhancement filtering in three-dimensional MR angiograms using long-range signal correlation

被引:30
作者
Du, YP [1 ]
Parker, DL [1 ]
机构
[1] UNIV UTAH,HLTH SCI CTR,DEPT RADIOL,SALT LAKE CITY,UT 84132
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1997年 / 7卷 / 02期
关键词
contrast enhancement; image filtering; image processing; vascular studies; interpolation;
D O I
10.1002/jmri.1880070234
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Small vessels in three-dimensional BIR angiograms have low visibility in maximum-intensity projection images because of their low contrast. In a previous study, we had two nonlinear filters that appeared to give significant improvement in small vessel detail. In this paper, we report on a generalization of this filter that allows a more general modeling of the vessels and a more complete suppression of background, One implementation of the general filter gave a vessel mean contrast-to-noise ratio that is 2.52 and 3.51 times higher than the vessel mean contrast-to-noise ratio obtained using our previously reported maximum-minimum (max-min) filter and cross- section filter, respectively.
引用
收藏
页码:447 / 450
页数:4
相关论文
共 19 条
  • [1] ARTIFACTS IN MAXIMUM-INTENSITY-PROJECTION DISPLAY OF MR ANGIOGRAMS
    ANDERSON, CM
    SALONER, D
    TSURUDA, JS
    SHAPEERO, LG
    LEE, RE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (03) : 623 - 629
  • [2] CONTRAST-TO-NOISE RATIOS IN MAXIMUM INTENSITY PROJECTION IMAGES
    BROWN, DG
    RIEDERER, SJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) : 130 - 137
  • [3] AN ALGORITHM FOR MR-ANGIOGRAPHY IMAGE-ENHANCEMENT
    CHEN, HG
    HALE, J
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (04) : 534 - 540
  • [4] CONTRAST-TO-NOISE-RATIO MEASUREMENTS IN 3-DIMENSIONAL MAGNETIC-RESONANCE ANGIOGRAPHY
    DU, YP
    PARKER, DL
    DAVIS, WL
    BLATTER, DD
    [J]. INVESTIGATIVE RADIOLOGY, 1993, 28 (11) : 1004 - 1009
  • [5] DU YP, 1995, P SOC MAGN RES MED, P581
  • [6] DU YP, 1993, P SOC MAGN RES MED B, P704
  • [7] DU YP, 1993, P SOC MAGN RES MED B, P454
  • [8] REDUCTION OF PARTIAL-VOLUME ARTIFACTS WITH ZERO-FILLED INTERPOLATION IN 3-DIMENSIONAL MR-ANGIOGRAPHY
    DU, YPP
    PARKER, DL
    DAVIS, WL
    CAO, G
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05): : 733 - 741
  • [9] VESSEL ENHANCEMENT FILTERING IN 3-DIMENSIONAL MR-ANGIOGRAPHY
    DU, YPP
    PARKER, DL
    DAVIS, WL
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03): : 353 - 359
  • [10] VISUALIZATION OF VASCULATURE FROM VOLUME DATA
    EHRICKE, HH
    DONNER, K
    KOLLER, W
    STRASSER, W
    [J]. COMPUTERS & GRAPHICS-UK, 1994, 18 (03): : 395 - 406