Stereoacuity and aniseikonia after unilateral and bilateral implantation of the Array refractive multifocal intraocular lens

被引:33
作者
Häring, G [1 ]
Gronemeyer, A [1 ]
Hedderich, J [1 ]
de Decker, W [1 ]
机构
[1] Univ Kiel, Hosp Eye, Dept Gen Ophthalmol, Kiel, Germany
关键词
D O I
10.1016/S0886-3350(99)00136-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate stereoacuity and aniseikonia in eyes with unilateral and bilateral implantation of the Allergan Array(R) refractive multifocal intraocular lens (MIOL). Setting: Department of Ophthalmology, University Hospital, Kiel, Germany. Methods: This study comprised 31 patients with a unilateral MIOL and a phakic fellow eye and 29 patients with bilateral MIOLs. in all pseudophakic eyes, an Array MIOL had been implanted between 1991 and 1994 during a prospective clinical trial. In the present study, patients were re-examined. Near and distance visual acuity were i tested; binocular functions were assessed using Bagolini lenses, the Worth 4-dot test, the Lang random-dot test, and the Titmus fly chart. Aniseikonia was evaluated using Aulhorn's phase-difference haploscope. Mean follow-up was 43 months in both groups. Results: After unilateral implantation 87.1% of patients and after bilateral implantation 93.1% of patients correctly perceived the stereograms of the Lang random-dot test. The mean subjective height of the measured Titmus fly was 4.2 cm after unilateral and 4.3 cm after bilateral implantation. The stereoacuity tests revealed no statistically significant differences between the groups. Distance and near aniseikonia were significantly less after bilateral than after unilateral implantation. Conclusion: Despite the simultaneous formation of multiple retinal images, the Array MIOL allowed good binocular vision including random-dot stereopsis. Functional aniseikonia developed but did not interfere with normal binocular vision. (C) 1999 ASCRS and ESCRS.
引用
收藏
页码:1151 / 1156
页数:6
相关论文
共 28 条
[21]  
Schmidt Friederike U., 1994, Ophthalmologe, V91, P469
[22]  
SCHMIDT FU, 1996, 9 K DEUTSCHSPR GES I, P212
[23]  
STEINERT RF, 1992, OPHTHALMOLOGY, V99, P853
[24]   The luminous efficiency of rays entering the eye pupil at different points. [J].
Stiles, WS ;
Crawford, BH .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES B-CONTAINING PAPERS OF A BIOLOGICAL CHARACTER, 1933, 112 (778) :428-450
[25]   Visual function with monofocal versus multifocal IOLs [J].
Vaquero, M ;
Encinas, JL ;
Jimenez, F .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (09) :1222-1225
[26]   AMO Array multifocal versus monofocal intraocular lenses: Long-term follow-up [J].
Vaquero-Ruano, M ;
Encinas, JL ;
Millan, I ;
Hijos, M ;
Cajigal, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (01) :118-123
[27]  
WAGNER R, 1996, 9 K DEUTSCHSPR GES I, P208
[28]   CONTRAST SENSITIVITY, GLARE, AND VISUAL FUNCTION - DIFFRACTIVE MULTIFOCAL VERSUS BILATERAL MONOFOCAL INTRAOCULAR LENSES [J].
WINTHERNIELSEN, A ;
GYLDENKERNE, G ;
CORYDON, L .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1995, 21 (02) :202-207