Electronic monitoring of medication adherence: When is high-tech best?

被引:123
作者
Riekert, KA [1 ]
Rand, CS [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Div Pulm & Crit Care Med, Baltimore, MD 21224 USA
关键词
adherence; compliance; measurement; electronic monitoring; MEMS; MDIlog; Doser;
D O I
10.1023/A:1014131928789
中图分类号
B849 [应用心理学];
学科分类号
040203 ;
摘要
The accurate measurement of medication adherence is challenging, particularly in pediatrics. Electronic monitoring has been proposed as a possible "gold standard" for medication adherence measurement. Electronic monitoring permits the evaluation of patterns of medication use and dose-response relationship and may be a useful part of adherence promotion interventions. The use of these devices, however, is not without costs and cautions including, expense, malfunctioning, and interference with existing adherence routines. This review examines the costs and benefits of using electronic monitoring of adherence as well as the reliability and validity of electronic monitoring in general and, where possible, for specific devices (i.e., MEMS, MDIlog, and Doser). Finally, we provide recommendations for quality control protocols to minimize many of the problems encountered when using such devices. Ultimately, the choice of adherence measurement strategy should be based on the goal of the study and the resources available.
引用
收藏
页码:25 / 34
页数:10
相关论文
共 41 条
  • [11] MICROELECTRONIC SYSTEMS FOR MONITORING AND ENHANCING PATIENT COMPLIANCE WITH MEDICATION REGIMENS
    CRAMER, JA
    [J]. DRUGS, 1995, 49 (03) : 321 - 327
  • [12] Fallab-Stubi CL, 1998, INT J TUBERC LUNG D, V2, P525
  • [13] Methods for measuring and monitoring medication regimen adherence in clinical trials and clinical practice
    Farmer, KC
    [J]. CLINICAL THERAPEUTICS, 1999, 21 (06) : 1074 - 1090
  • [14] Compliance with tricyclic antidepressants: the value of four different methods of assessment
    George, CF
    Peveler, RC
    Heiliger, S
    Thompson, C
    [J]. BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2000, 50 (02) : 166 - 171
  • [15] METERED-DOSE INHALER USAGE IN SUBJECTS WITH ASTHMA - COMPARISON OF NEBULIZER CHRONOLOG AND DAILY DIARY RECORDINGS
    GONG, H
    SIMMONS, MS
    CLARK, VA
    TASHKIN, DP
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1988, 82 (01) : 5 - 10
  • [16] A design for testing interventions to improve adherence within a hypertension clinical trial
    Johnson, BF
    Hamilton, G
    Fink, J
    Lucey, G
    Bennet, N
    Lew, R
    [J]. CONTROLLED CLINICAL TRIALS, 2000, 21 (01): : 62 - 72
  • [18] LIU H, 2001, ANN INTERN MED, V134, P1004
  • [19] CRITICAL COMPARISON OF NOVEL AND EXISTING METHODS OF COMPLIANCE ASSESSMENT DURING A CLINICAL-TRIAL OF AN ORAL IRON CHELATOR
    MATSUI, D
    HERMANN, C
    KLEIN, J
    BERKOVITCH, M
    OLIVIERI, N
    KOREN, G
    [J]. JOURNAL OF CLINICAL PHARMACOLOGY, 1994, 34 (09) : 944 - 949
  • [20] Noncompliance and treatment failure in children with asthma
    Milgrom, H
    Bender, B
    Ackerson, L
    Bowry, P
    Smith, B
    Rand, C
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1996, 98 (06) : 1051 - 1057