Improved accuracy of pedicle screw insertion with computer-assisted surgery - A prospective clinical trial of 30 patients

被引:224
作者
Laine, T
Schlenzka, D
Makitalo, K
Tallroth, K
Nolte, LP
Visarius, H
机构
[1] ORTON ORTHOPAED HOSP,INVALID FDN,HELSINKI,FINLAND
[2] UNIV BERN,ME MULLER INST BIOMECH,BERN,SWITZERLAND
关键词
computed tomographic scan analysis; computer assistance; image guidance; pedicle fixation; spinal surgery;
D O I
10.1097/00007632-199706010-00018
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A prospective clinical trial was done to study the accuracy of pedicle screw placement in 30 consecutive computer-assisted orthopedic surgeries. Objectives. To determine the accuracy and clinical applicability of this new method for pedicle screw insertion. Summary of Background Data. Conventional screw insertion techniques have been associated with high pedicle screw malplacement rates in cadaver studies and clinical studies with postoperative computer tomography evaluation. Methods. Thirty transpedicular, low-back, titanium instrumentations were performed with computer-assisted orthopedic surgery. The accuracy of screw placement was evaluated using a sophisticated computed tomography protocol. Results. The total number of pedicle screws was 174. Of these, 139 (79.9%) could be inserted with computer-assisted orthopedic surgery. The malplacement rate of computer-assisted orthopedic surgery screws was 4.3%. In screws that were not inserted by computer assisted orthopedic surgery, the malplacement rate was 14.3%. One malplaced screw that had not been inserted with computer-assisted orthopedic surgery caused L4 root paresis. Conclusions. The accuracy of pedicle screw placement using computer-assisted surgery proved to be superior to the accuracy obtained when using conventional techniques.
引用
收藏
页码:1254 / 1258
页数:5
相关论文
共 14 条
[1]   COMPLICATIONS ASSOCIATED WITH THE TECHNIQUE OF PEDICLE SCREW FIXATION - A SELECTED SURVEY OF ABS MEMBERS [J].
ESSES, SI ;
SACHS, BL ;
DREYZIN, V .
SPINE, 1993, 18 (15) :2231-2239
[2]  
GEORGE DC, 1991, SPINE, V16, P181, DOI 10.1097/00007632-199116020-00015
[3]   ACCURACY OF PEDICULAR SCREW PLACEMENT INVIVO [J].
GERTZBEIN, SD ;
ROBBINS, SE .
SPINE, 1990, 15 (01) :11-14
[4]  
Grevitt M P, 1995, Eur Spine J, V4, P169, DOI 10.1007/BF00298241
[5]   ACCURACY OF PEDICLE SCREWS IN DORSAL LUMBAR SPINAL-FUSION [J].
JEROSCH, J ;
MALMS, J ;
CASTRO, WHM ;
WAGNER, R ;
WIESNER, L .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1992, 130 (06) :479-483
[6]  
Nolte L P, 1995, J Image Guid Surg, V1, P88, DOI 10.1002/(SICI)1522-712X(1995)1:2<88::AID-IGS3>3.0.CO
[7]  
2-H
[8]   CLINICAL-EVALUATION OF A SYSTEM FOR PRECISION ENHANCEMENT IN SPINE SURGERY [J].
NOLTE, LP ;
ZAMORANO, L ;
VISARIUS, H ;
BERLEMANN, U ;
LANGLOTZ, F ;
ARM, E ;
SCHWARZENBACH, O .
CLINICAL BIOMECHANICS, 1995, 10 (06) :293-303
[9]   IMAGE-GUIDED INSERTION OF TRANSPEDICULAR SCREWS - A LABORATORY SET-UP [J].
NOLTE, LP ;
ZAMORANO, LJ ;
JIANG, ZW ;
WANG, QH ;
LANGLOTZ, F ;
BERLEMANN, U .
SPINE, 1995, 20 (04) :497-500
[10]  
NOLTE LP, 1995, 22 ANN M INT SOC STU