Capillary gas chromatography coupled with microplasma mass spectrometry for organotin speciation

被引:12
作者
Brede, C
Pedersen-Bjergaard, S
Lundanes, E
Greibrokk, T
机构
[1] Univ Oslo, Dept Chem, N-0315 Oslo, Norway
[2] Univ Oslo, Sch Pharm, N-0316 Oslo, Norway
关键词
mass spectrometry; microplasma mass spectrometry; organotin compounds;
D O I
10.1016/S0021-9673(99)00561-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Gas chromatography was coupled with microplasma mass spectrometry for selective detection of organotin compounds. The microplasma ion source was a capacitively coupled radiofrequency helium plasma, which was located inside the high vacuum area of the mass spectrometer. Only 1-3 mi min(-1) of helium carrier gas from the gas chromatograph was necessary for sustaining the plasma while 0.15-1.5 ml min(-1) of hydrogen was added as reagent gas. Hydrogen was applied for prevention of carbon deposition and served to minimize the interactions between tin and the fused-silica inner surface of the microplasma ion source. Both carbon and tin were detected as positively charged atomic ions, which were expelled from the microplasma ion source and directly focused by electrostatic lenses towards the quadrupole mass analyzer. Tin exhibited high selectivity to carbon (>10(4)) and a detection limit of 3.5 pg s(-1). (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:553 / 562
页数:10
相关论文
共 39 条
[1]   Speciation of organotin compounds released from poly(vinyl chloride) at increased temperature by gas chromatography with atomic emission detection [J].
Becker, G ;
Janak, K ;
Colmsjo, A ;
Ostman, C .
JOURNAL OF CHROMATOGRAPHY A, 1997, 775 (1-2) :295-306
[2]   Radiofrequency glow discharge as an ion source for gas chromatography with mass spectrometric detection [J].
Belkin, MA ;
Olson, LK ;
Caruso, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (11) :1255-1261
[3]   EFFECTS OF DOPANTS ON TIN EMISSION IN A HELIUM MICROWAVE-INDUCED PLASMA [J].
BESNER, A ;
HUBERT, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (02) :381-385
[4]  
Brede C, 1998, HRC-J HIGH RES CHROM, V21, P633
[5]  
Brede C, 1998, HRC-J HIGH RES CHROM, V21, P282
[6]   Microplasma mass spectrometric detection in capillary gas chromatography [J].
Brede, C ;
Pedersen-Bjergaard, S ;
Lundanes, E ;
Greibrokk, T .
ANALYTICAL CHEMISTRY, 1998, 70 (03) :513-518
[7]  
BREDE C, Patent No. 970707
[8]   Integrated sample preparation and speciation analysis for the simultaneous determination of methylated species of tin, lead and mercury in water by purge-and-trap injection-capillary gas chromatography atomic emission spectrometry [J].
Ceulemans, M ;
Adams, FC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (03) :201-206
[9]   Evaluation of derivatization techniques for the analysis of organotin compounds in biological tissue [J].
Chau, YK ;
Yang, F ;
Brown, M .
ANALYTICA CHIMICA ACTA, 1997, 338 (1-2) :51-55
[10]  
CLARKSON TW, 1991, INORGANIC ORGANOMETA