Radiofrequency glow discharge as an ion source for gas chromatography with mass spectrometric detection

被引:35
作者
Belkin, MA [1 ]
Olson, LK [1 ]
Caruso, JA [1 ]
机构
[1] UNIV CINCINNATI,DEPT CHEM,CINCINNATI,OH 45221
关键词
radiofrequency glow discharge; mass spectrometry; ion source; capillary gas chromatography; organotin;
D O I
10.1039/a700266a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A radiofrequency (rf) powered glow discharge (GD) has been used as an ion source for GC-MS. The improved GC-GD interface has allowed separation and detection of five organotin compounds with better figures of merit than previously reported. Limits of detection for four compounds were from 0.6 to 13 picogram (as tin). Optimization of the discharge pressure and sampling distance with respect to the primary analytical species of interest, elemental tin, has been performed, Characterization of the source has been made by studying the effect of the cell pressure, applied rf power and sampling distance on analyte signal and organotin fragmentation patterns. The results obtained indicate that the mass spectra generated do not differ significantly with the varying source pressure and rf power as they exhibit the same features in terms of parent-molecular peaks and fragment ions.
引用
收藏
页码:1255 / 1261
页数:7
相关论文
共 35 条
[1]   EFFECT OF DISCHARGE CONDITIONS ON THE SPUTTERING AND SPATIAL-DISTRIBUTION OF ATOMS IN A RADIOFREQUENCY GLOW-DISCHARGE ATOMIZER FOR ATOMIC-ABSORPTION SPECTROMETRY [J].
ABSALAN, G ;
CHAKRABARTI, CL ;
HUTTON, JC ;
BACK, MH ;
LAZIK, C ;
MARCUS, RK .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (01) :45-52
[2]   PRELIMINARY-STUDY OF THE ROLE OF DISCHARGE CONDITIONS ON THE IN-DEPTH ANALYSIS OF CONDUCTING THIN-FILMS BY RADIOFREQUENCY GLOW-DISCHARGE OPTICAL-EMISSION SPECTROMETRY [J].
BORDELGARCIA, N ;
PEREIROGARCIA, R ;
FERNANDEZGARCIA, M ;
SANZMEDEL, A ;
HARVILLE, TR ;
MARCUS, RK .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (09) :671-676
[3]   CHARACTERIZATION OF A GLOW-DISCHARGE ION-SOURCE FOR THE MASS-SPECTROMETRIC ANALYSIS OF ORGANIC-COMPOUNDS [J].
CARAZZATO, D ;
BERTRAND, MJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (04) :305-315
[4]  
Chapman BN, 1980, Glow Discharges Processes J, DOI DOI 10.1063/1.2914660
[5]  
CHAPMAN JR, 1987, J CHROMATOGR, V394, P321
[6]   PLASMA DIAGNOSTICS OF AN RF-SPUTTERING GLOW DISCHARGE [J].
COBURN, JW ;
KAY, E .
APPLIED PHYSICS LETTERS, 1971, 18 (10) :435-&
[7]   PARAMETER EVALUATION FOR THE ANALYSIS OF OXIDE-BASED SAMPLES WITH RADIO-FREQUENCY GLOW-DISCHARGE MASS-SPECTROMETRY [J].
DEGENDT, S ;
VANGRIEKEN, RE ;
OHORODNIK, SK ;
HARRISON, WW .
ANALYTICAL CHEMISTRY, 1995, 67 (06) :1026-1033
[8]  
DEPALMA PA, 1995, 43 ASMS C MASS SPECT
[9]   DESIGN AND CHARACTERIZATION OF A RADIO-FREQUENCY-POWERED GLOW-DISCHARGE SOURCE FOR DOUBLE-FOCUSING MASS SPECTROMETERS [J].
DUCKWORTH, DC ;
DONOHUE, DL ;
SMITH, DH ;
LEWIS, TA ;
MARCUS, RK .
ANALYTICAL CHEMISTRY, 1993, 65 (18) :2478-2484
[10]   RADIO-FREQUENCY POWERED GLOW-DISCHARGE ATOMIZATION IONIZATION SOURCE FOR SOLIDS MASS-SPECTROMETRY [J].
DUCKWORTH, DC ;
MARCUS, RK .
ANALYTICAL CHEMISTRY, 1989, 61 (17) :1879-1886