PARAMETER EVALUATION FOR THE ANALYSIS OF OXIDE-BASED SAMPLES WITH RADIO-FREQUENCY GLOW-DISCHARGE MASS-SPECTROMETRY

被引:32
作者
DEGENDT, S
VANGRIEKEN, RE
OHORODNIK, SK
HARRISON, WW
机构
[1] UNIV FLORIDA,DEPT CHEM,GAINESVILLE,FL 32611
[2] UNIV INSTELLING ANTWERP,DEPT CHEM,B-2610 ANTWERP,BELGIUM
关键词
D O I
10.1021/ac00102a002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The performance of radio frequency-powered glow discharge mass spectrometry (rf-GDMS) has been evaluated for the direct analysis of nonconducting samples, The parameters under study are the discharge power, the discharge pressure, the sample versus exit orifice distance, and the effect of cryogenic cooling. Optimum conditions are used to evaluate some analytical figures bf merit for the analysis of compacted oxide-based materials. A precision of better than 5% is obtained on all measured species in the discharge, and a semiquantitative analysis delivers results within a factor of 2 from the certified concentrations. Relative sensitivity factors are reported and compared for various matrices. The analytical data demonstrate the potential capabilities of rf-GDMS for direct analysis of various kinds of nonconducting materials.
引用
收藏
页码:1026 / 1033
页数:8
相关论文
共 29 条
[1]  
ABSALAN G, 1994, J ANAL ATOM SPECTROS, V9, P47
[2]   DETERMINATION OF URANIUM AND THORIUM IN BASALTS AND URANIUM IN AQUEOUS-SOLUTION BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
BAILEY, EH ;
KEMP, AJ ;
RAGNARSDOTTIR, KV .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (04) :551-556
[3]  
BRUHN CG, 1978, ANAL CHEM, V50, P353
[4]   NEW TECHNIQUE FOR ELEMENTAL ANALYSIS OF THIN SURFACE LAYERS OF SOLIDS [J].
COBURN, JW ;
KAY, E .
APPLIED PHYSICS LETTERS, 1971, 19 (09) :350-&
[5]  
DOGAN M, 1973, Z ANAL CHEM, V263, P1
[6]   RADIOFREQUENCY CAVITY ION-SOURCE IN SOLIDS MASS-SPECTROMETRY [J].
DONOHUE, DL ;
HARRISON, WW .
ANALYTICAL CHEMISTRY, 1975, 47 (09) :1528-1531
[7]   DESIGN AND CHARACTERIZATION OF A RADIO-FREQUENCY-POWERED GLOW-DISCHARGE SOURCE FOR DOUBLE-FOCUSING MASS SPECTROMETERS [J].
DUCKWORTH, DC ;
DONOHUE, DL ;
SMITH, DH ;
LEWIS, TA ;
MARCUS, RK .
ANALYTICAL CHEMISTRY, 1993, 65 (18) :2478-2484
[8]   RADIO-FREQUENCY POWERED GLOW-DISCHARGE ATOMIZATION IONIZATION SOURCE FOR SOLIDS MASS-SPECTROMETRY [J].
DUCKWORTH, DC ;
MARCUS, RK .
ANALYTICAL CHEMISTRY, 1989, 61 (17) :1879-1886
[9]   DIRECT INSERTION PROBE FOR RADIOFREQUENCY POWERED GLOW-DISCHARGE MASS-SPECTROMETRY [J].
DUCKWORTH, DC ;
MARCUS, RK .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (04) :711-715
[10]   ATOMIC EMISSION AND ATOMIC-ABSORPTION SPECTROMETRIC ANALYSIS OF HIGH-PURITY POWDERS FOR THE PRODUCTION OF CERAMICS [J].
GRAULE, T ;
VONBOHLEN, A ;
BROEKAERT, JAC ;
GRALLATH, E ;
KLOCKENKAMPER, R ;
TSCHOPEL, P ;
TOLG, G .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 335 (07) :637-642