Confounding effects of myocardial background intensity and attenuation in contrast echocardiography:: An in vivo study

被引:3
作者
Bos, LJ
Piek, JJ
Vergroesen, I
Spaan, JAE
机构
[1] Univ Amsterdam, Inst Cardiovasc Res, Acad Med Ctr, Dept Cardiol, NL-1100 DD Amsterdam, Netherlands
[2] Univ Amsterdam, Inst Cardiovasc Res, Acad Med Ctr, Dept Med Phys, NL-1100 DD Amsterdam, Netherlands
关键词
contrast echocardiography; attenuation; ultrasound; background intensity; infoson; dogs; transit rate;
D O I
10.1016/S0301-5629(99)00080-0
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
It has been shown in vitro that the time-intensity data of echo contrast agents may be influenced by the background intensity of the myocardium and attenuation at high contrast agent concentrations. In the present study, these effects are evaluated from in vivo data, An effect of background intensity of the myocardium on the determination of the transit rate of the contrast agent could not be demonstrated unambiguously, A statistically significant relation between transit rate and background intensity was found only for intermediate flows in the transmural region. The magnitude of this relation was such that it does not provide a serious source of error. Attenuation and shadowing typically underestimate the transit rate of the contrast agent, which results in overestimation of how, It is recommended that the lowest doses of contrast agent inducing myocardial opacification should be applied, (C) 1999 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1177 / 1184
页数:8
相关论文
共 21 条
  • [1] Effects of shadowing on the time-intensity curves in contrast echocardiography: A phantom study
    Bos, LJ
    Piek, JJ
    Spaan, JAE
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (02) : 217 - 227
  • [2] BACKGROUND SUBTRACTION FROM TIME-INTENSITY CURVES IN VIDEODENSITOMETRY - A PITFALL IN FLOW ASSESSMENT USING CONTRAST ECHOCARDIOGRAPHY
    BOS, LJ
    PIEK, JJ
    SPAAN, JAE
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (09) : 1211 - 1218
  • [3] BOS LJ, 1997, THESIS U AMSTERDAM
  • [4] FLUORESCENT VS RADIOACTIVE MICROSPHERE MEASUREMENT OF REGIONAL MYOCARDIAL BLOOD-FLOW
    CHIEN, GL
    ANSELONE, CG
    DAVIS, RF
    VANWINKLE, DM
    [J]. CARDIOVASCULAR RESEARCH, 1995, 30 (03) : 405 - 412
  • [5] ABSORPTION AND SCATTER OF ENCAPSULATED GAS FILLED MICROSPHERES - THEORETICAL CONSIDERATIONS AND SOME MEASUREMENTS
    DEJONG, N
    HOFF, L
    SKOTLAND, T
    BOM, N
    [J]. ULTRASONICS, 1992, 30 (02) : 95 - 103
  • [6] Gigli G, 1995, J Am Soc Echocardiogr, V8, P475, DOI 10.1016/S0894-7317(05)80334-7
  • [7] VALIDATION OF FLUORESCENT-LABELED MICROSPHERES FOR MEASUREMENT OF REGIONAL ORGAN PERFUSION
    GLENNY, RW
    BERNARD, S
    BRINKLEY, M
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (05) : 2585 - 2597
  • [8] Relation between air-filled albumin microbubble and red blood cell rheology in the human myocardium - Influence of echocardiographic systems and chest wall attenuation
    Ismail, S
    Jayaweera, AR
    Camarano, G
    Gimple, LW
    Powers, ER
    Kaul, S
    [J]. CIRCULATION, 1996, 94 (03) : 445 - 451
  • [9] Jayaweera A R, 1994, J Am Soc Echocardiogr, V7, P590
  • [10] IN-VIVO MYOCARDIAL KINETICS OF AIR-FILLED ALBUMIN MICROBUBBLES DURING MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY - COMPARISON WITH RADIOLABELED RED-BLOOD-CELLS
    JAYAWEERA, AR
    EDWARDS, N
    GLASHEEN, WP
    VILLANUEVA, FS
    ABBOTT, RD
    KAUL, S
    [J]. CIRCULATION RESEARCH, 1994, 74 (06) : 1157 - 1165