First-pass myocardial perfusion MR imaging with outer-volume suppression and the intravascular contrast agent NC1001150 injection:: Preliminary results in eight patients

被引:9
作者
Bjerner, T [1 ]
Johansson, L
Ericsson, A
Wilkström, G
Hemmingsson, A
Ahlström, H
机构
[1] Univ Uppsala Hosp, Dept Radiol, S-75185 Uppsala, Sweden
[2] Univ Uppsala Hosp, Dept Cardiol, S-75185 Uppsala, Sweden
[3] Nycomed Amersham Imaging, Oslo, Norway
关键词
heart; perfusion; magnetic resonance (MR); contrast; enhancement; myocardium; blood supply; MR;
D O I
10.1148/radiol.2213010220
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors evaluated the feasibility of combining single-shot T2-weighted turbo spin-echo magnetic resonance (MR) imaging and first-pass myocardial perfusion MR imaging with an intravascular ultrasmall superparamagnetic iron oxide (USPIO) contrast agent, NC100150 Injection (3 mg of iron per kilogram of body weight). Eight patients with coronary vessel disease underwent T2-weighted turbo spin-echo MR imaging (inplane resolution, 1-2 mm) during the first pass of the USPIO contrast agent. The mean decrease in signal intensity in myocardium perfused by a nonstenotic coronary artery was 59% +/- 13 (SD) (P < .012) This method is feasible for imaging of myocardial perfusion.
引用
收藏
页码:822 / 826
页数:5
相关论文
共 14 条
[1]   Noninvasive detection of myocardial ischemia from perfusion reserve based on cardiovascular magnetic resonance [J].
Al-Saadi, N ;
Nagel, E ;
Gross, M ;
Bornstedt, A ;
Schnackenburg, B ;
Klein, C ;
Klimek, W ;
Oswald, H ;
Fleck, E .
CIRCULATION, 2000, 101 (12) :1379-1383
[2]  
Bauer WR, 1999, MAGN RESON MED, V42, P1004, DOI 10.1002/(SICI)1522-2594(199912)42:6<1004::AID-MRM2>3.0.CO
[3]  
2-M
[4]  
BOGEYMAN JL, 1995, MAGNET RESON MED, V34, P555
[5]   MB-guided biopsy using a T2-weighted single-shot zoom imaging sequence (Local Look technique) [J].
Buecker, A ;
Adam, G ;
Neuerburg, JM ;
Glowinski, A ;
van Vaals, JJ ;
Guenther, RW .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (04) :955-959
[6]   Improved coverage in dynamic contrast-enhanced cardiac MRI using interleaved gradient-echo EPI [J].
Ding, SJ ;
Wolff, SD ;
Epstein, FH .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (04) :514-519
[7]   Direct comparison of an intravascular and an extracellular contrast agent for quantification of myocardial perfusion [J].
Jerosch-Herold, M ;
Wilke, N ;
Wang, Y ;
Gong, GR ;
Mansoor, AM ;
Huang, H ;
Gurchumelidze, S ;
Stillman, AE .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1999, 15 (06) :453-464
[8]  
Kellar KE, 2000, JMRI-J MAGN RESON IM, V11, P488
[9]  
Panting JR, 1999, JMRI-J MAGN RESON IM, V10, P404, DOI 10.1002/(SICI)1522-2586(199909)10:3<404::AID-JMRI23>3.0.CO
[10]  
2-V