Improved coverage in dynamic contrast-enhanced cardiac MRI using interleaved gradient-echo EPI

被引:87
作者
Ding, SJ
Wolff, SD
Epstein, FH
机构
[1] NHLBI, Cardiac Energet Lab, NIH, Bethesda, MD 20892 USA
[2] Gen Elect Med Syst, Appl Sci Lab, Waukesha, WI USA
关键词
myocardium; perfusion; first-pass; contrast enhancement;
D O I
10.1002/mrm.1910390403
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An interleaved gradient-echo echo-planar imaging (IGEPI) sequence was modified for and applied to dynamic contrast-enhanced imaging of the heart. Using IGEPI, images with 3.0 x 3.9 mm nominal in-plane resolution are acquired in 100 ms, enabling eight slices per heartbeat for a heart rate of 60 beats/min. The acquisition speed and use of saturation pre; pulses allows acquisition of short-and long-axis images during the same contrast bolus. IGEPI maintains the acquisition characteristics required for performing a quantitative first-pass perfusion analysis as well as providing improved coverage compared with conventional fast gradient echo.
引用
收藏
页码:514 / 519
页数:6
相关论文
共 34 条
  • [1] 1ST-PASS CARDIAC PERFUSION - EVALUATION WITH ULTRAFAST MR IMAGING
    ATKINSON, DJ
    BURSTEIN, D
    EDELMAN, RR
    [J]. RADIOLOGY, 1990, 174 (03) : 757 - 762
  • [2] BASSINGTHWAIGHT.JB, 1993, NUCL CARDIOLOGY STAT, P3
  • [3] DIRECT COMPARISON OF [N-13] AMMONIA AND [O-15]WATER ESTIMATES OF PERFUSION WITH QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW BY MICROSPHERES
    BOL, A
    MELIN, JA
    VANOVERSCHELDE, JL
    BAUDHUIN, T
    VOGELAERS, D
    DEPAUW, M
    MICHEL, C
    LUXEN, A
    LABAR, D
    COGNEAU, M
    ROBERT, A
    HEYNDRICKX, GR
    WIJNS, W
    [J]. CIRCULATION, 1993, 87 (02) : 512 - 525
  • [4] CHO ZH, 1987, P SMRM 6 ANN M NEW Y, P912
  • [5] ELIMINATION OF TRANSVERSE COHERENCES IN FLASH MRI
    CRAWLEY, AP
    WOOD, ML
    HENKELMAN, RM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1988, 8 (03) : 248 - 260
  • [6] Technical note - Approach to myocardial perfusion with echo planar imaging
    Debatin, JF
    McKinnon, GC
    vonSchulthess, GK
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 1996, 4 (01): : 7 - 11
  • [7] CONTRAST-ENHANCED ECHO-PLANAR MR-IMAGING OF MYOCARDIAL PERFUSION - PRELIMINARY-STUDY IN HUMANS
    EDELMAN, RR
    LI, W
    [J]. RADIOLOGY, 1994, 190 (03) : 771 - 777
  • [8] ISCHEMIC-HEART-DISEASE - ASSESSMENT WITH GADOLINIUM-ENHANCED ULTRAFAST MR-IMAGING AND DIPYRIDAMOLE STRESS
    EICHENBERGER, AC
    SCHUIKI, E
    KOCHLI, VD
    AMANN, FW
    MCKINNON, GC
    VONSCHULTHESS, GK
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03) : 425 - 431
  • [9] Spoiling of transverse magnetization in gradient-echo (GRE) imaging during the approach to steady state
    Epstein, FH
    Mugler, JP
    Brookeman, JR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (02) : 237 - 245
  • [10] ANALYSIS OF T2 LIMITATIONS AND OFF-RESONANCE EFFECTS ON SPATIAL-RESOLUTION AND ARTIFACTS IN ECHO-PLANAR IMAGING
    FARZANEH, F
    RIEDERER, SJ
    PELC, NJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) : 123 - 139