Spoiling of transverse magnetization in gradient-echo (GRE) imaging during the approach to steady state

被引:50
作者
Epstein, FH
Mugler, JP
Brookeman, JR
机构
[1] UNIV VIRGINIA, HLTH SCI CTR, DEPT RADIOL, CHARLOTTESVILLE, VA 22908 USA
[2] UNIV VIRGINIA, HLTH SCI CTR, DEPT BIOMED ENGN, CHARLOTTESVILLE, VA 22908 USA
关键词
rapid imaging; computer simulations; pulse sequences;
D O I
10.1002/mrm.1910350216
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The signal evolution behaviors and corresponding image appearances for different methods of spoiling or refocusing the transverse magnetization in short TR gradient-echo imaging during the approach to steady state were investigated experimentally and using computer simulations based on the Bloch equations. Specifically, ideally spoiled, gradient-spoiled, gradient-refocused, and RF-spoiled pulse sequence configurations were studied. This study showed that, for the gradient-spoiled configuration, the signal evolution is position and phase-encoding order-dependent and, under typical imaging conditions, can deviate substantially from the ideally spoiled signal evolution at some spatial positions, resulting in intensity banding image artifacts. For the gradient-refocused configuration, the signal evolution oscillates toward the steady state and, generally, does not closely approximate that of ideal spoiling, resulting in different image contrast or image blurring. Using RF spoiling, the signal evolution closely approximates the ideally spoiled case for flip angles less than approximately 20 degrees and T-2 values of less than approximately 200 ms and results in relatively artifact-free images. Also, this study showed that, for RF spoiling, an RF-pulse phase-difference increment other than 117 degrees, such as 84 degrees, may be optimal for gradient-echo imaging during the approach to steady state.
引用
收藏
页码:237 / 245
页数:9
相关论文
共 31 条
[1]   CINEANGIOGRAPHY OF THE HEART IN A SINGLE BREATH HOLD WITH A SEGMENTED TURBOFLASH SEQUENCE [J].
ATKINSON, DJ ;
EDELMAN, RR .
RADIOLOGY, 1991, 178 (02) :357-360
[2]   A REVIEW OF H-1 NUCLEAR-MAGNETIC-RESONANCE RELAXATION IN PATHOLOGY - ARE T1 AND T2 DIAGNOSTIC [J].
BOTTOMLEY, PA ;
HARDY, CJ ;
ARGERSINGER, RE ;
ALLENMOORE, G .
MEDICAL PHYSICS, 1987, 14 (01) :1-37
[3]   MP RAGE - A 3-DIMENSIONAL, T1-WEIGHTED, GRADIENT-ECHO SEQUENCE - INITIAL EXPERIENCE IN THE BRAIN [J].
BRANTZAWADZKI, M ;
GILLAN, GD ;
NITZ, WR .
RADIOLOGY, 1992, 182 (03) :769-775
[4]   STRATEGIES TO IMPROVE CONTRAST IN TURBOFLASH IMAGING - REORDERED PHASE ENCODING AND K-SPACE SEGMENTATION [J].
CHIEN, D ;
ATKINSON, DJ ;
EDELMAN, RR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (01) :63-70
[5]   ELIMINATION OF TRANSVERSE COHERENCES IN FLASH MRI [J].
CRAWLEY, AP ;
WOOD, ML ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1988, 8 (03) :248-260
[6]   MAGNETIZATION PREPARED RAPID GRADIENT-ECHO (MP-RAGE) MR IMAGING OF THE LIVER - COMPARISON WITH SPIN-ECHO IMAGING [J].
DELANGE, EE ;
MUGLER, JP ;
BERTOLINA, JA ;
GAY, SB ;
JANUS, CL ;
BROOKEMAN, JR .
MAGNETIC RESONANCE IMAGING, 1991, 9 (04) :469-476
[7]   MR-IMAGING OF THE LIVER - BREATH-HOLD T1-WEIGHTED MP-GRE COMPARED WITH CONVENTIONAL T2-WEIGHTED SE IMAGING - LESION DETECTION, LOCALIZATION, AND CHARACTERIZATION [J].
DELANGE, EE ;
MUGLER, JP ;
BOSWORTH, JE ;
DEANGELIS, GA ;
GAY, SB ;
HURT, NS ;
BERR, SS ;
ROSENBLATT, JM ;
MERICKEL, LW ;
HARRIS, EK .
RADIOLOGY, 1994, 190 (03) :727-736
[8]   CORONARY-ARTERIES - BREATH-HOLD MR ANGIOGRAPHY [J].
EDELMAN, RR ;
MANNING, WJ ;
BURSTEIN, D ;
PAULIN, S .
RADIOLOGY, 1991, 181 (03) :641-643
[9]   IMPROVED T1-WEIGHTED 2-DIMENSIONAL MP-GRE IMAGING OF THE LIVER WITH VARIABLE FLIP ANGLES FOR SHAPING THE SIGNAL EVOLUTION [J].
EPSTEIN, FH ;
MUGLER, JP ;
BROOKEMAN, JR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (01) :91-98
[10]   INVERSION IN THE STEADY-STATE - CONTRAST OPTIMIZATION AND REDUCED IMAGING TIME WITH FAST 3-DIMENSIONAL INVERSION-RECOVERY - PREPARED GRE PULSE SEQUENCES [J].
FOO, TKF ;
SAWYER, AM ;
FAULKNER, WH ;
MILLS, DG .
RADIOLOGY, 1994, 191 (01) :85-90