IMPROVED T1-WEIGHTED 2-DIMENSIONAL MP-GRE IMAGING OF THE LIVER WITH VARIABLE FLIP ANGLES FOR SHAPING THE SIGNAL EVOLUTION

被引:6
作者
EPSTEIN, FH [1 ]
MUGLER, JP [1 ]
BROOKEMAN, JR [1 ]
机构
[1] UNIV VIRGINIA,HLTH SCI CTR,DEPT RADIOL,MRI FACIL,CHARLOTTESVILLE,VA 22908
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1994年 / 4卷 / 01期
关键词
LIVER; MR; MODEL; MATHEMATICAL; PULSE SEQUENCES; RAPID IMAGING;
D O I
10.1002/jmri.1880040118
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The recently introduced method of shaping the transient signal evolution in magnetization-prepared gradient-echo (MP-GRE) imaging with variable flip angles has been applied to two-dimensional (2D) MP-GRE imaging of the abdomen. The technique was analyzed by using theoretical models and was implemented on a standard 1.5-T whole-body imager with a segmented acquisition. Theoretical models predicted that the variable-flip-angle 2D MP-GRE sequence would increase liver-spleen signal difference-to-noise ratios by 290%, 110%, and 160% compared with a 2D MP-GRE sequence with a flip angle of 10-degrees and sequential phase encoding. a 2D MP-GRE sequence with a flip angle of 30-degrees and centric phase encoding, and the fast low-angle shot sequence, respectively. Experimental measurements supported the theoretical predictions.
引用
收藏
页码:91 / 98
页数:8
相关论文
共 18 条
[1]   RESPIRATORY ORDERED PHASE ENCODING (ROPE) - A METHOD FOR REDUCING RESPIRATORY MOTION ARTIFACTS IN MR IMAGING [J].
BAILES, DR ;
GILDERDALE, DJ ;
BYDDER, GM ;
COLLINS, AG ;
FIRMIN, DN .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :835-838
[2]   MAGNETIZATION PREPARED RAPID GRADIENT-ECHO (MP-RAGE) MR IMAGING OF THE LIVER - COMPARISON WITH SPIN-ECHO IMAGING [J].
DELANGE, EE ;
MUGLER, JP ;
BERTOLINA, JA ;
GAY, SB ;
JANUS, CL ;
BROOKEMAN, JR .
MAGNETIC RESONANCE IMAGING, 1991, 9 (04) :469-476
[3]   SELECTIVE VERSUS NONSELECTIVE PREPARATION PULSES IN 2-DIMENSIONAL MP-RAGE IMAGING OF THE LIVER [J].
DELANGE, EE ;
MUGLER, JP ;
BERTOLINA, JA ;
BROOKEMAN, JR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03) :355-358
[4]  
DROBNITZKY M, 1992, BOOK ABSTRACTS SOC M, P4406
[5]   SEGMENTED TURBOFLASH - METHOD FOR BREATH-HOLD MR IMAGING OF THE LIVER WITH FLEXIBLE CONTRAST [J].
EDELMAN, RR ;
WALLNER, B ;
SINGER, A ;
ATKINSON, DJ ;
SAINI, S .
RADIOLOGY, 1990, 177 (02) :515-521
[6]   RAPID MR IMAGING WITH SUSPENDED RESPIRATION - CLINICAL-APPLICATION IN THE LIVER [J].
EDELMAN, RR ;
HAHN, PF ;
BUXTON, R ;
WITTENBERG, J ;
FERRUCCI, JT ;
SAINI, S ;
BRADY, TJ .
RADIOLOGY, 1986, 161 (01) :125-131
[7]   TRANSVERSE COHERENCE IN RAPID FLASH NMR IMAGING [J].
FRAHM, J ;
HANICKE, W ;
MERBOLDT, KD .
JOURNAL OF MAGNETIC RESONANCE, 1987, 72 (02) :307-314
[8]   THE IMPORTANCE OF PHASE-ENCODING ORDER IN ULTRA-SHORT TR SNAPSHOT MR IMAGING [J].
HOLSINGER, AE ;
RIEDERER, SJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (03) :481-488
[9]   T1-WEIGHTED SNAPSHOT GRADIENT-ECHO MR IMAGING OF THE ABDOMEN [J].
HOLSINGERBAMPTON, AE ;
RIEDERER, SJ ;
CAMPEAU, NG ;
EHMAN, RL ;
JOHNSON, CD .
RADIOLOGY, 1991, 181 (01) :25-32
[10]   SHAPING THE SIGNAL RESPONSE DURING THE APPROACH TO STEADY-STATE IN 3-DIMENSIONAL MAGNETIZATION-PREPARED RAPID GRADIENT-ECHO IMAGING USING VARIABLE FLIP ANGLES [J].
MUGLER, JP ;
EPSTEIN, FH ;
BROOKEMAN, JR .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (02) :165-185