Validity of the diffusion approximation in bio-optical imaging

被引:38
作者
Chen, BQ [1 ]
Stamnes, K
Stamnes, JJ
机构
[1] Stevens Inst Technol, Dept Phys & Engn Phys, Hoboken, NJ 07030 USA
[2] Univ Bergen, Dept Phys, N-5007 Bergen, Norway
关键词
D O I
10.1364/AO.40.006356
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Accurate numerical simulations based on rigorous radiative transfer theory are used to assess the validity of the diffusion approximation that is frequently used in bio-optical imaging. These simulations show that the error is large for a non-index-matched boundary between air and tissue. This weakness of the diffusion approximation underscores the need to understand how diffusion theory can be used to extract accurate values of tissue optical properties. A validity criterion for the diffusion approximation is established on the basis of the single-scattering albedo a and the asymmetry factor g for a slab with index-matched boundaries. (C) 2001 Optical Society of America.
引用
收藏
页码:6356 / 6366
页数:11
相关论文
共 38 条
[21]   DIFFUSION OF LIGHT IN TURBID MATERIAL [J].
ISHIMARU, A .
APPLIED OPTICS, 1989, 28 (12) :2210-2215
[22]   DIFFUSION OF A PULSE IN DENSELY DISTRIBUTED SCATTERERS [J].
ISHIMARU, A .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1978, 68 (08) :1045-1050
[23]  
Ishimaru A., 1997, WAVE PROPAGATION SCA
[24]   RADIATIVE-TRANSFER IN NONUNIFORMLY REFRACTING LAYERED MEDIA - ATMOSPHERE OCEAN SYSTEM [J].
JIN, ZH ;
STAMNES, K .
APPLIED OPTICS, 1994, 33 (03) :431-442
[25]   Optical diffusion of continuous-wave, pulsed, and density waves in scattering media and comparisons with radiative transfer [J].
Kim, AD ;
Ishimaru, A .
APPLIED OPTICS, 1998, 37 (22) :5313-5319
[26]   Near-field diffraction tomography with diffuse photon density waves [J].
Li, XD ;
Pattanayak, DN ;
Durduran, T ;
Culver, JP ;
Chance, B ;
Yodh, AG .
PHYSICAL REVIEW E, 2000, 61 (04) :4295-4309
[27]   TIME RESOLVED REFLECTANCE AND TRANSMITTANCE FOR THE NONINVASIVE MEASUREMENT OF TISSUE OPTICAL-PROPERTIES [J].
PATTERSON, MS ;
CHANCE, B ;
WILSON, BC .
APPLIED OPTICS, 1989, 28 (12) :2331-2336
[28]   Quantifying the properties of two-layer turbid media with frequency-domain diffuse reflectance [J].
Pham, TH ;
Spott, T ;
Svaasand, LO ;
Tromberg, BJ .
APPLIED OPTICS, 2000, 39 (25) :4733-4745
[29]   Optical properties of circulating human blood in the wavelength range 400-2500 NM [J].
Roggan, A ;
Friebel, M ;
Dörschel, K ;
Hahn, A ;
Müller, G .
JOURNAL OF BIOMEDICAL OPTICS, 1999, 4 (01) :36-46
[30]   Design and evaluation of a continuous-wave diffuse optical tomography system [J].
Siegel, AM ;
Marota, JJA ;
Boas, DA .
OPTICS EXPRESS, 1999, 4 (08) :287-298