Simple microfabrication method of glass plate using high-viscosity photoresist for micro analytical systems

被引:8
作者
Fujii, S [1 ]
Tokuyama, T [1 ]
Abo, M [1 ]
Okubo, A [1 ]
机构
[1] Univ Tokyo, Grad Sch Agr & Life Sci, Dept Appl Biol Chem, Bunkyo Ku, Tokyo 1138657, Japan
关键词
D O I
10.1039/b314726f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have developed a method for microfabrication on a glass plate by photolithography using a high-viscosity photoresist as an etching mask. This fabrication method does not require the coating and etching of thin metal (Au/Cr) layers on the glass; therefore, the use of this photoresist has made simple and rapid microfabrication possible in a general laboratory. By this method, the etching time of glass was prolonged by as much as 100 min (about 100 mum depth) in an ammonium hydrogenfluoride etchant using an 800 cP photoresist and a borosilicate glass plate. The fabricated glass template was of even quality, and the precision of the reproduction of the glass plate was calculated (e. g., 0.74% RSD, n = 3, 2 pt). A relief with a minimum width of 81.5 mum was fabricated within several hours. We used the fabricated glass for the template of a polymer microchip for environmental analysis. The fluorometric analysis on the PDMS microchip was well demonstrated. The calibration curve of sulfite showed good linearity (R-2 = 0.998). Moreover, an environmental sample was analyzed utilizing this microchip.
引用
收藏
页码:305 / 308
页数:4
相关论文
共 17 条
[1]  
AKASAKA K, 1993, J AOAC INT, V76, P1385
[2]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[3]   An integrated fluorescence detection system in poly(dimethylsiloxane) for microfluidic applications [J].
Chabinyc, ML ;
Chiu, DT ;
McDonald, JC ;
Stroock, AD ;
Christian, JF ;
Karger, AM ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2001, 73 (18) :4491-4498
[4]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[5]   MICROMACHINING OF CAPILLARY ELECTROPHORESIS INJECTORS AND SEPARATORS ON GLASS CHIPS AND EVALUATION OF FLOW AT CAPILLARY INTERSECTIONS [J].
FAN, ZH ;
HARRISON, DJ .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :177-184
[6]   Fluorometric determination of sulrite and nitrite in aqueous samples using a novel detection unit of a microfluidic device [J].
Fujii, S ;
Tokuyama, T ;
Abo, M ;
Okubo, A .
ANALYTICAL SCIENCES, 2004, 20 (01) :209-212
[7]  
FUJII S, 2003, MICRO TOTAL ANAL SYS, V7, P391
[8]  
GAMAO K, 1994, RES REPORTS KOCHI U, V43, P91
[9]  
Hong JW, 2001, ELECTROPHORESIS, V22, P328
[10]   Surface modification of poly(dimethylsiloxane) microfluidic devices by ultraviolet polymer grafting [J].
Hu, SW ;
Ren, XQ ;
Bachman, M ;
Sims, CE ;
Li, GP ;
Allbritton, N .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :4117-4123