Contrast-enhanced, ultrafast 3D pulmonary MR angiography in a single breath-hold: Initial assessment of imaging performance

被引:59
作者
Steiner, P [1 ]
McKinnon, GC [1 ]
Romanowski, B [1 ]
Goehde, SC [1 ]
Hany, T [1 ]
Debatin, JF [1 ]
机构
[1] UNIV ZURICH HOSP, DEPT RADIOL, CH-8091 ZURICH, SWITZERLAND
关键词
magnetic resonance (MR); three-dimensional; pulmonary arteries; MR; vascular studies; magnetic resonance (MR) rapid imaging; VASCULATURE; EXPERIENCE; STRATEGIES; EMBOLISM; FLOW;
D O I
10.1002/jmri.1880070127
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An ultrafast three-dimensional (3D) sequence was developed, enabling the acquisition of 44 contiguous 2.0- to 2.2-mm thin sections, during intravenous application of paramagnetic contrast, in a single breath-hold. To estimate the potential clinical usefulness, images were assessed qualitatively and quantitatively with regard to visibility of main, lobar, segmental, and subsegmental pulmonary arteries. Five volunteers were examined using a 192 x 192 matrix with an imaging time of 23 seconds and five other volunteers with a 160 x 160 matrix (18 seconds). Each volunteer was imaged in apnea and during shallow respiration. The breath-held 23-second scans revealed excellent image quality and near complete visualization of central and segmental, as well as 81% of subsegmental, pulmonary arteries. Imaging time can be shortened to 18 seconds with only marginal loss in visualization performance (P < .05). Respiratory motion was found to cause significant worsening of image quality and vessel detectability. To maintain relevance in a clinical setting, imaging time can be minimized at the cost of a reduction in spatial resolution.
引用
收藏
页码:177 / 182
页数:6
相关论文
共 31 条
[1]   CLINICAL FEATURES OF SUBMASSIVE AND MASSIVE PULMONARY EMBOLI [J].
BELL, WR ;
SIMON, TL ;
DEMETS, DL .
AMERICAN JOURNAL OF MEDICINE, 1977, 62 (03) :355-360
[2]   ECHOCARDIOGRAPHIC EVALUATION OF PULMONARY-EMBOLISM AND ITS RESPONSE TO THERAPEUTIC INTERVENTIONS [J].
COME, PC .
CHEST, 1992, 101 (04) :S151-S162
[3]   Human aorta: Preliminary results with virtual endoscopy based on three-dimensional MR imaging data sets [J].
Davis, CP ;
Ladd, ME ;
Romanowski, BJ ;
Wildermuth, S ;
Knoplioch, JF ;
Debatin, JF .
RADIOLOGY, 1996, 199 (01) :37-40
[4]  
FOO TK, 1996, SOC MAGNETIC RESONAN, P453
[5]   SINGLE-BREATH-HOLD VENOUS OR ARTERIAL FLOW SUPPRESSED PULMONARY VASCULAR MR-IMAGING WITH PHASED-ARRAY COILS [J].
FOO, TKF ;
MACFALL, JR ;
SOSTMAN, HD ;
HAYES, CE .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (04) :611-616
[6]   CARDIAC-GATED MR-ANGIOGRAPHY OF PULSATILE FLOW - K-SPACE STRATEGIES [J].
FRANCK, A ;
SELBY, K ;
VANTYEN, R ;
NORDELL, B ;
SALONER, D .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03) :297-307
[7]  
GEFTER WB, 1993, J THORAC IMAG, V7, P208
[8]   DETECTION OF PULMONARY-EMBOLISM IN PATIENTS WITH UNRESOLVED CLINICAL AND SCINTIGRAPHIC DIAGNOSIS - HELICAL CT VERSUS ANGIOGRAPHY [J].
GOODMAN, LR ;
CURTIN, JJ ;
MEWISSEN, MW ;
FOLEY, WD ;
LIPCHIK, RJ ;
CRAIN, MR ;
SAGAR, KB ;
COLLIER, BD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (06) :1369-1374
[9]   PULMONARY ANGIOGRAPHY WITH MR-IMAGING - PRELIMINARY CLINICAL-EXPERIENCE [J].
GRIST, TM ;
SOSTMAN, HD ;
MACFALL, JR ;
FOO, TK ;
SPRITZER, CE ;
WITTY, L ;
NEWMAN, GE ;
DEBATIN, JF ;
TAPSON, V ;
SALTZMAN, HA .
RADIOLOGY, 1993, 189 (02) :523-530
[10]  
GRIST TM, 1996, SOC MAGNETIC RESONAN, P163