On-line determination of cyanide in the presence of sulfide by flow injection with pervaporation

被引:36
作者
Sulistyarti, H
Cardwell, TJ
de Castro, MDL
Kolev, SD [1 ]
机构
[1] La Trobe Univ, Ctr Sci Instrumentat, Dept Chem, Bundoora, Vic 3083, Australia
[2] Univ Cordoba, Fac Sci, Dept Analyt Chem, E-14004 Cordoba, Spain
基金
澳大利亚研究理事会;
关键词
pervaporation; flow injection; cyanide determination; sulfide intereference; distillation;
D O I
10.1016/S0003-2670(99)00158-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A pervaporation-flow injection (PFI) method is described for the analysis of cyanide in the presence of sulfide. The interfering sulfide ion in the injected sample is precipitated on-line using an acidified lead nitrate reagent solution before the donor stream enters the pervaporation cell. Using amperometric detection at a silver electrode set at -50 mV (vs Ag/AgCl), linear calibration was obtained in the range 0.02-100.0 mg l(-1) with a detection limit of 1.0 mu g l(-1). Sample throughput was of the order of 12-15 h(-1). When the method was applied to the analysis of synthetic samples, there was no significant interference from sulfide at concentrations up to 50 mg l(-1). Thiocyanate did not interfere at levels up to 1000 mg l(-1). When applied to industrial samples containing sulfide and thiocyanate ions where the cyanide ions are predominantly complexed with various metal ions the PFI method was found to give results close to those obtained by standard distillation methods for weak acid dissociable (WAD) cyanide. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:133 / 139
页数:7
相关论文
共 24 条
[1]  
[Anonymous], 1992, STAND METH EX WAT WA
[2]  
Backofen U, 1996, FRESEN J ANAL CHEM, V356, P271
[3]   Anticoagulation in children with mechanical valve prostheses [J].
Bradley, SM ;
Sade, RM ;
Crawford, FA ;
Stroud, MR .
ANNALS OF THORACIC SURGERY, 1997, 64 (01) :30-36
[4]   Continuous microwave assisted pervaporation/atomic fluorescence detection: An approach for speciation in solid samples [J].
Bryce, DW ;
Izquierdo, A ;
deCastro, MDL .
ANALYTICA CHIMICA ACTA, 1996, 324 (01) :69-75
[5]   Enzymatic interference-free assay for oxalate in urine [J].
Canizares, P ;
deCastro, MDL .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (06) :777-781
[6]  
de Castro ML, 1998, TRAC-TREND ANAL CHEM, V17, P41
[7]   Strategies for solid sample treatment [J].
deCastro, MDL ;
daSilva, MP .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1997, 16 (01) :16-24
[8]   OXIDATIVE AMPEROMETRIC FLOW-INJECTION DETERMINATION OF CYANIDE AT AN ELECTROCHEMICALLY PRETREATED GLASSY-CARBON ELECTRODE [J].
FOGG, AG ;
ALONSO, RM .
ANALYST, 1987, 112 (07) :1071-1072
[9]   GAS-DIFFUSION SEPARATION AND FLOW-INJECTION POTENTIOMETRY - A FRUITFUL ALLIANCE OF ANALYTICAL METHODS [J].
FRENZEL, W .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 336 (01) :21-28
[10]   Determination of trimethylamine in fish by pervaporation and photometric detection [J].
GarciaGarrido, JA ;
deCastro, MDL .
ANALYST, 1997, 122 (07) :663-666