Concordance between M-mode, pulsed Tissue Doppler, and colour Tissue Doppler in the assessment of mitral annulus systolic excursion in normal subjects

被引:26
作者
Ballo, Piercarlo [1 ]
Bocelli, Arianna
Motto, Andrea [1 ]
Mondillo, Sergio [2 ,3 ]
机构
[1] St Andreas Hosp, Cardiol Operat Unit, I-19100 La Spezia, Italy
[2] Univ Siena, Dept Cardiovasc Dis, I-53100 Siena, Italy
[3] Univ Florence, Meyer Hosp, Florence, Italy
来源
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY | 2008年 / 9卷 / 06期
关键词
Doppler Tissue imaging; M-mode; Mitral annular systolic motion;
D O I
10.1093/ejechocard/jen130
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims M-mode left atrioventricular plane displacement (AVPD) correlates with Tissue Doppler (TD) peak systolic annular velocity in healthy individuals. This approach is biased by several interacting factors related to the structural complexity of mitral annulus physiology, including the different dimensional values of measures, the confounding effect of isovolumic motions, and the spectral thickness of pulsed TD envelope. We sought to analyze the effective concordance between techniques in the assessment of systolic annular excursion. Methods and results In 92 healthy subjects (age 60.5 +/- 18.6, 43.5% women), systolic AVPD was measured after exclusion of isovolumic components using three techniques: (i) M-mode; (ii) temporal integration of pulsed TD systolic wave; and (iii) colour TD-derived tissue tracking. Close correlations of M-mode AVPD with pulsed TD velocity-time integral (VTI) (R = 0.90, P < 0.0001) and colour TD AVPD (R = 0.86, P < 0.0001) were found. However, M-mode AVPD underestimated pulsed TD VTI (mean error -5.1 +/- 1.7 mm) and overestimated colour TD AVPD (mean error 3.4 +/- 1.3 mm). The concordance between M-mode and pulsed TD increased after adjustment for spectral dispersion of pulsed TD istantaneous velocities (mean error 0.1 +/- 1.1 mm). Conclusion Despite strict correlations exist between M-mode and TD in the assessment of mitral annulus systolic excursion, the effective concordance between techniques is sub-optimal.
引用
收藏
页码:748 / 753
页数:6
相关论文
共 23 条
[1]   Characteristics of mitral and tricuspid annular velocities determined by pulsed wave Doppler tissue imaging in healthy subjects [J].
Alam, M ;
Wardell, J ;
Andersson, E ;
Samad, BA ;
Nordlander, R .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (08) :618-628
[2]   Circumferential versus longitudinal systolic function in patients with hypertension: A nonlinear relation [J].
Ballo, Piercarlo ;
Quatrini, Ilaria ;
Giacomin, Elisa ;
Motto, Andrea ;
Mondillo, Sergio .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (03) :298-306
[3]   A novel method to assess systolic ventricular function using atrioventricular plane displacement -: a study in young healthy males and patients with heart disease [J].
Carlhäll, C ;
Hatle, L ;
Nylander, E .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2004, 24 (04) :190-195
[4]   Clinical in vivo calibration of pulse wave tissue Doppler velocities the assessment of ventricular wall motion. A comparison study with M-mode echocardiography [J].
Chen, QM ;
Li, W ;
O'Sullivan, C ;
Francis, DP ;
Gibson, D ;
Henein, MY .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2004, 97 (02) :289-295
[5]  
Dagum P, 2000, CIRCULATION, V102, P62
[6]   Mitral annular motion as a surrogate for teft ventricutar function: Corretation with brain natriuretic peptide levels [J].
Elnoamany, Mohamed Fahmy ;
Abdelhameed, Ayman Kilany .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2006, 7 (03) :187-198
[7]   CARDIAC DOPPLER BLOOD-FLOW SIGNAL ANALYSIS .1. EVALUATION OF THE NORMALITY AND STATIONARITY OF THE TEMPORAL SIGNAL [J].
GUO, Z ;
DURAND, LG ;
ALLARD, L ;
CLOUTIER, G ;
LEE, HC ;
LANGLOIS, YE .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 (03) :237-241
[8]   Analysis of mitral annulus motion measurements derived from M-mode, anatomic M-mode, tissue Doppler displacement, and 2-dimensional strain imaging [J].
Hayashi, Shirley Yumi ;
Lind, Britta I. ;
Seeberger, Astrid ;
do Nascimento, Marcelo Mazza ;
Lindholm, Bengt J. ;
Brodin, Lars-Ake .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2006, 19 (09) :1092-1101
[9]   Longitudinal isovolumic displacement of the left ventricular myocardium assessed by tissue velocity echocardiography in healthy individuals [J].
Lind, B ;
Eriksson, M ;
Roumina, S ;
Nowak, J ;
Brodin, LÅ .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2006, 19 (03) :255-265
[10]  
Lind B, 2004, Eur J Echocardiogr, V5, P284, DOI 10.1016/j.euje.2003.11.007