A novel method to assess systolic ventricular function using atrioventricular plane displacement -: a study in young healthy males and patients with heart disease

被引:18
作者
Carlhäll, C
Hatle, L
Nylander, E
机构
[1] Linkoping Univ Hosp, Dept Med & Care, SE-58185 Linkoping, Sweden
[2] Univ Hosp Gasthuisberg, Dept Cardiol, B-3000 Louvain, Belgium
关键词
echocardiography; overestimation; reference values; systolic performance; ventricular long axis motion;
D O I
10.1111/j.1475-097X.2004.00547.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Analysis of atrioventricular plane displacement (AVPD) is a well established method for assessment of both systolic and diastolic ventricular function. For several years, AVPD has been a clinical tool and there are many current, as well as potential, areas of application. However, clinical work has shown that the traditional method for evaluation of systolic ventricular function, called total AVPD, does not temporally reflect true systole. Systolic AVPD is a new approach for measuring AVPD to assess ventricular systolic function. We wished to apply this new model in healthy subjects and in patients with different common heart diseases. Twenty-eight young healthy males and 30 patients (aortic stenosis, left sided regurgitant lesions, postmyocardial infarction) were enrolled. AVPD was obtained at the four standard sites by M-mode. Total AVPD was measured in the conventional way and systolic AVPD by identifying true systole, by means of mitral- and aortic valve closure respectively. Ventricular volumes were calculated according to biplane Simpson's rule. The systolic AVPD measurements were significantly lower than the total measurements, at both atrioventricular planes in all groups (P<0.001). This discrepancy was greater at the mitral than at the tricuspid annulus in the patients 24.2% vs. 15.5% (P<0.001), but did not differ in the healthy subjects. At the mitral annulus, this discrepancy also seemed to be more pronounced in the patients than in the healthy subjects 24.2% vs. 10.7%. When assessing ventricular systolic function by AVPD, the conventional method overestimates the amplitude in relation to true systolic function in both patients with heart disease and in young healthy males. Thus, there are uncertainties regarding earlier estimations of AVPD in terms of expression of systolic function and regarding previously presented reference values. We recommend the proposed methodology.
引用
收藏
页码:190 / 195
页数:6
相关论文
共 33 条
[1]   Right ventricular function in patients with first inferior myocardial infarction: Assessment by tricuspid annular motion and tricuspid annular velocity [J].
Alam, M ;
Wardell, J ;
Andersson, E ;
Samad, BA ;
Nordlander, R .
AMERICAN HEART JOURNAL, 2000, 139 (04) :710-715
[2]  
Alam M, 1992, J Am Soc Echocardiogr, V5, P427
[3]   HEMODYNAMIC SIGNIFICANCE OF THE ATRIOVENTRICULAR PLANE DISPLACEMENT IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
ALAM, M ;
HOGLUND, C ;
THORSTRAND, C ;
HELLEKANT, C .
EUROPEAN HEART JOURNAL, 1992, 13 (02) :194-200
[4]  
ALAM M, 1991, EUR HEART J, V12, P760
[5]   Characteristics of mitral and tricuspid annular velocities determined by pulsed wave Doppler tissue imaging in healthy subjects [J].
Alam, M ;
Wardell, J ;
Andersson, E ;
Samad, BA ;
Nordlander, R .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (08) :618-628
[6]   Acute effects of smoking on diastolic function in healthy participants:: Studies by conventional Doppler echocardiography and Doppler tissue imaging [J].
Alam, M ;
Samad, BA ;
Wardell, J ;
Andersson, E ;
Höglund, C ;
Nordlander, R .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (10) :1232-1237
[7]   Assessment of left ventricular diastolic function from mitral annulus motion, a comparison with pulsed Doppler measurements in patients with heart failure [J].
Blomstrand, P ;
Kongstad, O ;
Broqvist, M ;
Dahlstrom, U ;
Wranne, B .
CLINICAL PHYSIOLOGY, 1996, 16 (05) :483-493
[8]   Is left ventricular postsystolic long-axis shortening a marker for severity of hypertensive heart disease? [J].
Carlhäll, C ;
Wranne, B ;
Jurkevicius, R .
AMERICAN JOURNAL OF CARDIOLOGY, 2003, 91 (12) :1490-1493
[9]  
Carlhall C-J, 1999, CLIN PHYSL, V19, P197
[10]   Atrioventricular plane displacement correlates closely to circulatory dimensions but not to ejection fraction in normal young subjects [J].
Carlhäll, CJ ;
Lindström, L ;
Wranne, B ;
Nylander, E .
CLINICAL PHYSIOLOGY, 2001, 21 (05) :621-628