A novel method to assess systolic ventricular function using atrioventricular plane displacement -: a study in young healthy males and patients with heart disease

被引:18
作者
Carlhäll, C
Hatle, L
Nylander, E
机构
[1] Linkoping Univ Hosp, Dept Med & Care, SE-58185 Linkoping, Sweden
[2] Univ Hosp Gasthuisberg, Dept Cardiol, B-3000 Louvain, Belgium
关键词
echocardiography; overestimation; reference values; systolic performance; ventricular long axis motion;
D O I
10.1111/j.1475-097X.2004.00547.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Analysis of atrioventricular plane displacement (AVPD) is a well established method for assessment of both systolic and diastolic ventricular function. For several years, AVPD has been a clinical tool and there are many current, as well as potential, areas of application. However, clinical work has shown that the traditional method for evaluation of systolic ventricular function, called total AVPD, does not temporally reflect true systole. Systolic AVPD is a new approach for measuring AVPD to assess ventricular systolic function. We wished to apply this new model in healthy subjects and in patients with different common heart diseases. Twenty-eight young healthy males and 30 patients (aortic stenosis, left sided regurgitant lesions, postmyocardial infarction) were enrolled. AVPD was obtained at the four standard sites by M-mode. Total AVPD was measured in the conventional way and systolic AVPD by identifying true systole, by means of mitral- and aortic valve closure respectively. Ventricular volumes were calculated according to biplane Simpson's rule. The systolic AVPD measurements were significantly lower than the total measurements, at both atrioventricular planes in all groups (P<0.001). This discrepancy was greater at the mitral than at the tricuspid annulus in the patients 24.2% vs. 15.5% (P<0.001), but did not differ in the healthy subjects. At the mitral annulus, this discrepancy also seemed to be more pronounced in the patients than in the healthy subjects 24.2% vs. 10.7%. When assessing ventricular systolic function by AVPD, the conventional method overestimates the amplitude in relation to true systolic function in both patients with heart disease and in young healthy males. Thus, there are uncertainties regarding earlier estimations of AVPD in terms of expression of systolic function and regarding previously presented reference values. We recommend the proposed methodology.
引用
收藏
页码:190 / 195
页数:6
相关论文
共 33 条
[11]   Long axis electromechanics during dobutamine stress in patients with coronary artery disease and left ventricular dysfunction [J].
Duncan, AM ;
O'Sullivan, CA ;
Carr-White, GS ;
Gibson, DG ;
Henein, MY .
HEART, 2001, 86 (04) :397-404
[12]   The relation between mitral annulus motion and ejection fraction: A nonlinear function [J].
Emilsson, K ;
Alam, M ;
Wandt, B .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2000, 13 (10) :896-901
[13]  
Emilsson K, 2000, CLIN PHYSIOL, V20, P218
[14]   The mode of left ventricular pumping: is there an outer contour change in addition to the atrioventricular plane displacement? [J].
Emilsson, K ;
Brudin, L ;
Wandt, B .
CLINICAL PHYSIOLOGY, 2001, 21 (04) :437-446
[15]   Right ventricular dysfunction in adult severe cystic fibrosis [J].
Florea, VG ;
Florea, ND ;
Sharma, R ;
Coats, AJS ;
Gibson, DG ;
Hodson, ME ;
Henein, MY .
CHEST, 2000, 118 (04) :1063-1068
[16]   Mitral annular descent velocity by tissue Doppler echocardiography as an index global left ventricular function [J].
Gulati, VK ;
Katz, WE ;
Follansbee, WP ;
Gorcsan, J .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (11) :979-984
[17]  
Hammarstrom E, 1991, J Am Soc Echocardiogr, V4, P131
[18]   Normal long axis function [J].
Henein, MY ;
Gibson, DG .
HEART, 1999, 81 (02) :111-113
[19]   Long axis function in disease [J].
Henein, MY ;
Gibson, DG .
HEART, 1999, 81 (03) :229-231
[20]  
HOGLUND C, 1988, ACTA MED SCAND, V224, P557