Heated mercury film electrode for anodic stripping voltammetry

被引:42
作者
Jasinski, M [1 ]
Kirbs, A [1 ]
Schmehl, M [1 ]
Gründler, P [1 ]
机构
[1] Univ Rostock, Fachbereich Chem, D-18051 Rostock, Germany
关键词
mercury film electrodes; heated electrodes; iridium; anodic stripping voltammetry; cadmium;
D O I
10.1016/S1388-2481(98)00008-3
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A directly heated mercury film electrode (MFE) extends the operational capabilities of the hot layer technique to a wide range of electroanalytical systems. Wires or layers of gold and platinum have been used as sensors so far, but they were suitable only for the analysis of a small number of metals. The development of a heated MFE is described, including electrode construction and mercury deposition procedures. The thermal properties of the sensor were investigated. As a first application, cadmium was determined by anodic stripping voltammetry (ASV) with the result of an improved signal-to-background ratio. (C) 1999 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:26 / 28
页数:3
相关论文
共 8 条
[1]   Mercury-plated iridium-based microelectrode arrays for trace metals detection by voltammetry: Optimum conditions and reliability [J].
Belmont, C ;
Tercier, ML ;
Buffle, J ;
Fiaccabrino, GC ;
KoudelkaHep, M .
ANALYTICA CHIMICA ACTA, 1996, 329 (03) :203-214
[2]   Deposition and stripping at heated microelectrodes. Arsenic(V) at a gold electrode [J].
Grundler, P ;
Flechsig, GU .
ELECTROCHIMICA ACTA, 1998, 43 (23) :3451-3458
[3]   Hot-wire electrodes: Voltammetry above the boiling point [J].
Grundler, P ;
Kirbs, A ;
Zerihun, T .
ANALYST, 1996, 121 (12) :1805-1810
[4]   Theory and practice of sensors with hot-wire electrodes [J].
Grundler, P .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 362 (02) :180-183
[5]   AN IRIDIUM BASED MERCURY ULTRAMICROELECTRODE - FABRICATION AND CHARACTERIZATION [J].
KOUNAVES, SP ;
DENG, W .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1991, 301 (1-2) :77-85
[6]   ANALYTICAL UTILITY OF THE IRIDIUM-BASED MERCURY ULTRAMICROELECTRODE WITH SQUARE-WAVE ANODIC-STRIPPING VOLTAMMETRY [J].
KOUNAVES, SP ;
DENG, W .
ANALYTICAL CHEMISTRY, 1993, 65 (04) :375-379
[7]   Electrically heated cylindrical microelectrodes. The reduction of dissolved oxygen on Pt [J].
Zerihun, T ;
Grundler, P .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 404 (02) :243-248
[8]   Electrically heated cylindrical microelectrodes. Determination of lead on Pt by cyclic voltammetry and cathodic stripping analysis [J].
Zerihun, T ;
Grundler, P .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 415 (1-2) :85-88