Triggering in quantitative diffusion imaging with single-shot EPI

被引:33
作者
Brockstedt, S [1 ]
Borg, M
Geijer, B
Wirestam, R
Thomsen, C
Holtås, S
Ståhlberg, F
机构
[1] Univ Lund Hosp, Dept Radiat Phys, Jubileum Inst, SE-22185 Lund, Sweden
[2] Univ Lund Hosp, Dept Diagnost Radiol, SE-22185 Lund, Sweden
[3] Copenhagen Univ Hosp, Rigshosp, Dept Radiol, Copenhagen, Denmark
关键词
MR imaging; echo-planar imaging; diffusion; electrocardiographic triggering; apparent diffusion coefficients;
D O I
10.3109/02841859909175552
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to evaluate any possible effects of brain motion, CSF pulsations and other possible sources of physiological motion in electrocardiographic (ECG) triggered and non-triggered single-shot echo-planar imaging (EPI) measurements of diffusion. Material and Methods. Three different triggering protocols were evaluated in 6 healthy volunteers: 1) ECG triggering with time delay (TD) 100 ms; 2) ECG triggering with TD 400 ms; and 3) no triggering at all. Results: The results obtained showed that white matter mean apparent diffusion coefficient (ADC) values were similar for all triggering protocols and that the reproducibility in ADC measurements using diffusion-weighted (DW) EPI was good. The average standard deviation of the ADC values was, however, higher for ADC maps obtained without ECG triggering. Conclusion: The use of prospective diastolic ECG triggering significantly improves the accuracy of quantitative diffusion measurements but for routine clinical diffusion imaging, where quantitative data is of less importance, the accuracy obtained without ECG triggering can be considered adequate.
引用
收藏
页码:263 / 269
页数:7
相关论文
共 20 条
[1]  
BROCKSTEDT S, 1995, ACTA RADIOL, V36, P662
[2]   Diffusion-weighted interleaved echo-planar imaging with a pair of orthogonal navigator echoes [J].
Butts, K ;
deCrespigny, A ;
Pauly, JM ;
Moseley, M .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) :763-770
[3]   ANISOTROPIC DIFFUSION IN HUMAN WHITE MATTER - DEMONSTRATION WITH MR TECHNIQUES INVIVO [J].
CHENEVERT, TL ;
BRUNBERG, JA ;
PIPE, JG .
RADIOLOGY, 1990, 177 (02) :401-405
[4]   MR DIFFUSION IMAGING OF THE HUMAN BRAIN [J].
CHIEN, D ;
BUXTON, RB ;
KWONG, KK ;
BRADY, TJ ;
ROSEN, BR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (04) :514-520
[5]   PULSATILE BRAIN MOVEMENT AND ASSOCIATED HYDRODYNAMICS STUDIED BY MAGNETIC-RESONANCE PHASE IMAGING - THE MONRO-KELLIE DOCTRINE REVISITED [J].
GREITZ, D ;
WIRESTAM, R ;
FRANCK, A ;
NORDELL, B ;
THOMSEN, C ;
STAHLBERG, F .
NEURORADIOLOGY, 1992, 34 (05) :370-380
[6]   Correction for distortion of echo-planar images used to calculate the apparent diffusion coefficient [J].
Haselgrove, JC ;
Moore, JR .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :960-964
[7]  
LEBIHAN D, 1993, NEUROREPORT, V4, P887
[8]   DIFFUSION IMAGING WITH THE MP-RAGE SEQUENCE [J].
LEE, H ;
PRICE, RR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (06) :837-842
[9]   The b matrix in diffusion tensor echo-planar imaging [J].
Mattiello, J ;
Basser, PJ ;
LeBihan, D .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) :292-300
[10]  
MOSELEY ME, 1990, AM J NEURORADIOL, V11, P423