Quasi-isoelectric buffers for protein analysis in a fast alternative to conventional capillary zone electrophoresis

被引:19
作者
Antonioli, P
Mendieta, ME
Sebastiano, R
Citterio, A
Peltre, G
Busnel, JM
Descroix, S
Candiano, G
Righetti, PG
机构
[1] Univ Verona, Dept Ind & Agr Biotechnol, I-37134 Verona, Italy
[2] Politecn Milan, Dept Chem, I-20131 Milan, Italy
[3] ESPCI, CNRS, UMR 7121, Lab Environm & Analyt Chem, F-75005 Paris, France
[4] G Gaslini Childrens Hosp, Lab Physiopathol Uremia, Genoa, Italy
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2006年 / 833卷 / 01期
关键词
ultra-narrow-pH ampholytes cuts; fractionation techniques; isoelectric buffer; uncoated-capillary CZE;
D O I
10.1016/j.jchromb.2005.10.017
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Two different approaches are here reported for obtaining ultra-narrow pI cuts from 2-pH unit wide carrier arnpholyte ranges, as commercially available, for use as quasi-isoelectric buffers in capillary electrophoresis separations of proteins. One of them uses multicompartment electrolyzers endowed with isoelectric membranes (Immobiline technology);. the other employs the Rotofor equipment. Although the first approach results in more precise pI cuts, the latter technique is much faster, easier to handle and permits the immediate collection of 20 fractions in a single run. This results in ultra-narrow, ca. 0.1-pH unit intervals, uniformly spaced apart along the original wider gradient utilized for the fractionation. It is here shown that such quasi-isoelectric buffers, especially those in the pH 8-9 interval, have the unique property of coating the silica wall, thus preventing interaction of the proteins with the silica surface, that would otherwise totally disrupt the separation. On the contrary, such a shielding is not obtained in control, non isoelectric buffers (such as phosphate), that give very poor separations in uncoated capillaries. It is hypothesized that such a unique shielding effect is due to the oligo-amino backbone of the carrier ampholytes, typically composed (in the Vesterberg's synthetic approach) of 4-6 nitrogens spaced apart by ethylene moieties. Although such oligoprotic buffers should bear, in the isoelectric state, just one positive and one negative charge, they might be transiently ionized upon contact with the silanols, thus inducing a cooperative binding to the silica wall. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:19 / 25
页数:7
相关论文
共 34 条
[1]   Ampholytes as background electrolytes in capillary zone electrophoresis: Sense or nonsense? Histidine as a model ampholyte [J].
Beckers, JL .
ELECTROPHORESIS, 2003, 24 (03) :548-556
[2]   DEPENDENCE OF THE ELECTROOSMOTIC MOBILITY ON THE APPLIED ELECTRIC-FIELD AND ITS REPRODUCIBILITY IN CAPILLARY ELECTROPHORESIS [J].
BELLO, MS ;
CAPELLI, L ;
RIGHETTI, PG .
JOURNAL OF CHROMATOGRAPHY A, 1994, 684 (02) :311-322
[3]   A NEW BUFFERING SYSTEM AND ITS USE IN ELECTROPHORESIS AND ISOELECTRIC-FOCUSING [J].
BIER, M ;
OSTREM, J ;
MARQUEZ, RB .
ELECTROPHORESIS, 1993, 14 (10) :1011-1018
[4]   RECYCLING ISOELECTRIC-FOCUSING - USE OF SIMPLE BUFFERS [J].
BIER, M ;
LONG, T .
JOURNAL OF CHROMATOGRAPHY, 1992, 604 (01) :73-83
[5]   MOLECULAR-WEIGHT DISTRIBUTION OF CARRIER AMPHOLYTES FOR ISOELECTRIC-FOCUSING [J].
BOSISIO, AB ;
SNYDER, RS ;
RIGHETTI, PG .
JOURNAL OF CHROMATOGRAPHY, 1981, 209 (02) :265-272
[6]   Generation of peptide maps by capillary zone electrophoresis in isoelectric iminodiacetic acid [J].
Bossi, A ;
Righetti, PG .
ELECTROPHORESIS, 1997, 18 (11) :2012-2018
[7]   General experimental aspects of the use of isoelectric buffers in capillary electrophoresis [J].
Bossi, A ;
Olivieri, E ;
Castelletti, L ;
Gelfi, C ;
Hamdan, M ;
Righetti, PG .
JOURNAL OF CHROMATOGRAPHY A, 1999, 853 (1-2) :71-82
[8]   Separation of peptides in isoelectric cysteic acid buffer and hydro-organic solvents (hexafluoro-2-propanol-urea) [J].
Bossi, A ;
Righetti, PG .
JOURNAL OF CHROMATOGRAPHY A, 1999, 840 (01) :117-129
[9]   FRACTIONATION OF CARRIER AMPHOLYTES IN MULTICOMPARTMENT ELECTROLYZERS WITH ISOELECTRIC MEMBRANES [J].
BOSSI, A ;
RIGHETTI, PG .
ELECTROPHORESIS, 1995, 16 (10) :1930-1934
[10]   Carrier ampholytes-based capillary electrophoresis as an alternative to capillary zone electrophoresis in classical background electrolytes [J].
Busnel, JM ;
Kilár, F ;
Kasicka, V ;
Descroix, S ;
Hennion, MC ;
Peltre, G .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1087 (1-2) :183-188