Evaluation of image quality using 1:1 pitch and 1.5:1 pitch helical CT in children: A comparative study

被引:41
作者
Vade, A [1 ]
Demos, TC [1 ]
Olson, MC [1 ]
Subbaiah, P [1 ]
Turbin, RC [1 ]
Vickery, K [1 ]
Corrigan, K [1 ]
机构
[1] OAKLAND UNIV,DEPT MATH SCI,ROCHESTER,MI 48309
关键词
D O I
10.1007/BF03178045
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective. The objective of this study was to compare the quality of 1 : 1 and 1.5 : 1 pitch helical contrast-enhanced thoracic and abdominal CT images in children who cannot cooperate for breath holding. Materials and methods This is a retrospective study of 33 contrast-enhanced CT examinations in 11 children of 0-4 years of age. All children had an initial CT study using 1 : 1 pitch helical scanning followed over the next 6-36 months by one to four CT examinations with 1.5 : 1 pitch. Radiation dose with the two techniques was measured with a pencil ionization chamber. Results. The two techniques provided comparable overall image quality. There was 33 % less radiation dose with 1.5 : 1 pitch helical scanning. Conclusion. The 1.5 : 1 pitch helical CT provides comparable quality images and a smaller radiation dose than 1 : 1 pitch in examining children aged 0-4 years.
引用
收藏
页码:891 / 893
页数:3
相关论文
共 10 条
  • [1] BRINK JA, 1992, RADIOLOGY, V185, P126
  • [2] SPIRAL CT - DECREASED SPATIAL-RESOLUTION INVIVO DUE TO BROADENING OF SECTION-SENSITIVITY PROFILE
    BRINK, JA
    HEIKEN, JP
    BALFE, DM
    SAGEL, SS
    DICROCE, J
    VANNIER, MW
    [J]. RADIOLOGY, 1992, 185 (02) : 469 - 474
  • [3] PULMONARY NODULE - EVALUATION WITH SPIRAL VOLUMETRIC CT
    COSTELLO, P
    ANDERSON, W
    BLUME, D
    [J]. RADIOLOGY, 1991, 179 (03) : 875 - 876
  • [4] SPIRAL CT OF THE PANCREAS
    DUPUY, DE
    COSTELLO, P
    ECKER, CP
    [J]. RADIOLOGY, 1992, 183 (03) : 815 - 818
  • [5] SPIRAL(HELICAL) CT
    HEIKEN, JP
    BRINK, JA
    VANNIER, MW
    [J]. RADIOLOGY, 1993, 189 (03) : 647 - 656
  • [6] SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION
    KALENDER, WA
    SEISSLER, W
    KLOTZ, E
    VOCK, P
    [J]. RADIOLOGY, 1990, 176 (01) : 181 - 183
  • [7] EVALUATION OF SECTION SENSITIVITY PROFILES AND IMAGE NOISE IN SPIRAL CT
    POLACIN, A
    KALENDER, WA
    MARCHAL, G
    [J]. RADIOLOGY, 1992, 185 (01) : 29 - 35
  • [8] CT OF THE CHEST AND ABDOMEN IN PATIENTS ON MECHANICAL PULMONARY VENTILATORS - QUALITY OF IMAGES MADE AT 0.6-SEC VS 1.0-SEC
    POSNIAK, HV
    OLSON, MC
    DEMOS, TC
    PIERCE, KL
    KALBHEN, CL
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (05) : 1073 - 1077
  • [9] PULMONARY NODULES - DETECTION WITH THICK-SECTION SPIRAL CT VERSUS CONVENTIONAL CT
    REMYJARDIN, M
    REMY, J
    GIRAUD, F
    MARQUETTE, CH
    [J]. RADIOLOGY, 1993, 187 (02) : 513 - 520
  • [10] DETECTION OF FOCAL HEPATIC-LESIONS WITH SPIRAL CT - COMPARISON OF 4-MM AND 8-MM INTERSCAN SPACING
    URBAN, BA
    FISHMAN, EK
    KUHLMAN, JE
    KAWASHIMA, A
    HENNESSEY, JG
    SIEGELMAN, SS
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (04) : 783 - 785