Comparison of an intercalating dye and an intercalant-enzyme conjugate for DNA detection in a microtiter-based assay

被引:7
作者
Kolakowski, B [1 ]
Battaglini, F [1 ]
Lee, YS [1 ]
Klironomos, G [1 ]
Mikkelsen, SR [1 ]
机构
[1] CONCORDIA UNIV,DEPT CHEM & BIOCHEM,MONTREAL,PQ H3G 1M8,CANADA
关键词
D O I
10.1021/ac950878m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two methods have been developed for the detection of DNA immobilized on the surface of microtiter wells. An intercalating dye, 3,6-diaminoacridine, is used in stain and rinse solutions, so that measured absorbance values (450 mn) reflect the sum of DNA-bound and free dye, With diaminoacridine, signal increases of 0.056 +/- 0.010 were achieved on immobilizing double-stranded calf thymus DNA. An intercalant-enzyme conjugate, consisting of an average of four daunomycin moieties covalently bound to each glucose oxidase, was shown to provide a 10 fold signal enhancement (optimum 0.25 mu M, with rinsing and peroxidases-dianisidine detection) compared to diaminoacridine, due to catalytic amplification; signals of 0.50 +/- 0.05 were obtained. This conjugate possesses 56% of the activity of native glucose oxidase and was prepared using water-soluble carbodiimide and N-hydroxysuccinimide reagents. Single-stranded DNA was immobilized onto avidin-coated polystyrene plates and commercially available (Covalink) plates possessing secondary amine groups. Following hybridization with complementary DNA, detection was performed with the daunomycin-glucose oxidase conjugate. Both immobilization methods showed optimum DNA concentrations of 0.10 mu g/mL, and maximum signal intensities were obtained when >0.5 mu g/mL complementary DNA was present in the hybridization solution. Some nonspecific binding of the intercalant-enzyme conjugate was suggested by results obtained with avidin-coated polystyrene plates, but not with Covalink plates.
引用
收藏
页码:1197 / 1200
页数:4
相关论文
共 18 条
[11]   SEQUENCE-SELECTIVE BIOSENSOR FOR DNA-BASED ON ELECTROACTIVE HYBRIDIZATION INDICATORS [J].
MILLAN, KM ;
MIKKELSEN, SR .
ANALYTICAL CHEMISTRY, 1993, 65 (17) :2317-2323
[12]   VOLTAMMETRIC DNA BIOSENSOR FOR CYSTIC-FIBROSIS BASED ON A MODIFIED CARBON-PASTE ELECTRODE [J].
MILLAN, KM ;
SARAULLO, A ;
MIKKELSEN, SR .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2943-2948
[13]   TIME-RESOLVED FLUOROMETRIC HYBRIDIZATION ASSAYS WITH RNA PROBES SYNTHESIZED FROM POLYMERASE CHAIN REACTION-GENERATED DNA TEMPLATES [J].
RADOVICH, P ;
BORTOLIN, S ;
CHRISTOPOULOS, TK .
ANALYTICAL CHEMISTRY, 1995, 67 (15) :2644-2649
[14]   P-31 NMR-STUDY OF DAUNORUBICIN-D(CGTACG) COMPLEX IN SOLUTION - EVIDENCE OF THE INTERCALATION SITES [J].
RAGG, E ;
MONDELLI, R ;
BATTISTINI, C ;
GARBESI, A ;
COLONNA, FP .
FEBS LETTERS, 1988, 236 (01) :231-234
[15]   COVALENT IMMOBILIZATION OF DNA ONTO POLYSTYRENE MICROWELLS - THE MOLECULES ARE ONLY BOUND AT THE 5' END [J].
RASMUSSEN, SR ;
LARSEN, MR ;
RASMUSSEN, SE .
ANALYTICAL BIOCHEMISTRY, 1991, 198 (01) :138-142
[16]   MOLECULAR-BIOLOGY TECHNIQUES [J].
SKOGERBOE, KJ .
ANALYTICAL CHEMISTRY, 1993, 65 (12) :R416-R419
[17]  
VARY CPH, 1992, CLIN CHEM, V38, P687
[18]  
*WORTH BIOCH CORP, 1972, WORTH ENZ MAN, P19