Background: Liver surgery can be difficult because there are few external landmarks defining hepatic anatomy and because the liver has significant vascularity. Although preoperative tomographic imaging (computed tomography or magnetic resonance imaging) provides essential anatomical information for operative planning, at present it cannot be used actively for precise localization during surgery. Interactive image-guided surgery involves the simultaneous real-time display of intraoperative instrument location on preoperative images (computed or positron-emission tomography or magnetic resonance imaging). Interactive image-guided surgery has been described for tumor localization in the brain (frameless stereotactic surgery) and allows for interactive use of preoperative images during resections or biopsies. Hypothesis: The application of interactive image-guided surgery (IIGS) is feasible for hepatic procedures from a biomedical engineering standpoint. Methods: We developed an interactive image-guided surgery system for liver surgery and tested a porcine liver model for tracking liver motion during insufflation; liver motion during respiration in open procedures in patients undergoing hepatic resection; and tracking accuracy of general surgical instruments, including a laparoscope and an ultrasound probe. Results: Liver motion due to insufflation can be quantified; average motion was 2.5 +/- 1.4 mm. Average total liver motion secondary to respiration in patients was 10.8 +/- 2.5 mm. Instruments of varying lengths, including a laparoscope, can be tracked to accuracies ranging from 1.4 to 2.1 mm within a 27-m(3) (3 X 3 X 3-m) space. Conclusion: Interactive image-guided surgery appears to be feasible for open and laparoscopic hepatic procedures and may enhance future operative localization.
引用
收藏
页码:644 / 649
页数:6
相关论文
共 17 条
[1]   PREOPERATIVE 3D RENDERING OF MR IMAGING IN LIVER METASTASES [J].
BENNETT, WF ;
BOVA, JG ;
PETTY, L ;
MARTIN, EW .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (06) :979-984
[2]   ULTRASOUND QUANTITATION OF RESPIRATORY ORGAN MOTION IN THE UPPER ABDOMEN [J].
DAVIES, SC ;
HILL, AL ;
HOLMES, RB ;
HALLIWELL, M ;
JACKSON, PC .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (803) :1096-1102
[3]   Image-guided endoscopic surgery: Results of accuracy and performance in a multicenter clinical study using an electromagnetic tracking system [J].
Fried, MP ;
Kleefield, J ;
Gopal, H ;
Reardon, E ;
Ho, BT ;
Kuhn, FA .
LARYNGOSCOPE, 1997, 107 (05) :594-601
[4]  
GALLOWAY RL, 1994, P SOC PHOTO-OPT INS, V2164, P137
[5]   INTERACTIVE IMAGE-GUIDED NEUROSURGERY [J].
GALLOWAY, RL ;
MACIUNAS, RJ ;
EDWARDS, CA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (12) :1226-1231
[6]  
GALLOWAY RL, 1993, INTERACTIVE IMAGE GU, P9
[7]   Automatic liver segmentation technique for three-dimensional visualisation of CT data [J].
Gao, LM ;
Heath, DG ;
Kuszyk, BS ;
Fishman, EK .
RADIOLOGY, 1996, 201 (02) :359-364
[8]  
HOH CK, 1993, J NUCL MED, V34, P2009
[9]   SUPERIOR STAGING OF LIVER-TUMORS WITH LAPAROSCOPY AND LAPAROSCOPIC ULTRASOUND [J].
JOHN, TG ;
GREIG, JD ;
CROSBIE, JL ;
MILES, WFA ;
GARDEN, OJ .
ANNALS OF SURGERY, 1994, 220 (06) :711-719
[10]  
KATKHOUDA N, 1996, PRINCIPLES LAPAROSCO, P345