Quartz crystal microbalances for quantitative biosensing and characterizing protein multilayers

被引:94
作者
Rickert, J
Brecht, A
Gopel, W
机构
[1] UNIV TUBINGEN,INST PHYS & THEORET CHEM,D-72076 TUBINGEN,GERMANY
[2] UNIV TUBINGEN,CTR INTERFACE ANAL & SENSORS,D-72076 TUBINGEN,GERMANY
关键词
quartz crystal microbalance; biosensors; affinity; protein multilayers;
D O I
10.1016/S0956-5663(96)00077-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The use of quartz crystal microbalances (QCMs) for quantitative biosensing and characterization of protein multilayers is demonstrated in three case studies. Monolayers of QCM-based affinity biosensors were investigated first. Layers of a thiol-containing synthetic peptide constituting an epitope of the foot-and-mouse-disease virus were formed on gold electrodes via self-assembly. The binding of specific antibodies to epitope-modified gold electrodes was detected for different concentrations of antibody solutions. Oligolayers were studied in a second set of experiments. Dextran hydrogels were modified by thrombin inhibitors. The QCM response was used in a competitive binding assay to identify inhibitors for thrombin at different concentrations. Multilayers of proteins formed by self-assembly of a biotin-conjugate and streptavidin were investigated next. The QCM frequency response was monitored as a function of layer thickness up to 20 protein layers. A linear frequency decay was observed with increasing thickness. The decay per layer remained constant, thus indicating perfect mass coupling to the substrate. Frequency changes a factor of four higher were obtained in buffer solution as compared to measurements in dry air. This indicates a significant incorporation of water (75% weight) in the protein layers. This water behaves like a solid concerning the shear mode coupling to the substrate. The outlook discusses briefly the need for controlled molecular engineering of overlayers for subsequent QCM analysis, and the importance of an additional multiparameter analysis with other transducer principles and with additional techniques of interface analysis to characterize the mechanical coupling of overlayers as biosensor coatings. A promising trend concerns the use of QCM-arrays for screening experiments. (C) 1997 Elsevier Science Limited.
引用
收藏
页码:567 / 575
页数:9
相关论文
共 20 条
  • [1] BONE S, 1992, BIOELECTRONICS, P89129
  • [2] BRECHT A, 1996, J BIOMOL SCREEN, V1, P191
  • [3] QUARTZ-CRYSTAL MICROBALANCE AND SURFACE-PLASMON RESONANCE STUDY OF SURFACTANT ADSORPTION ONTO GOLD AND CHROMIUM-OXIDE SURFACES
    CARUSO, F
    SERIZAWA, T
    FURLONG, DN
    OKAHATA, Y
    [J]. LANGMUIR, 1995, 11 (05) : 1546 - 1552
  • [4] PIEZOELECTRIC CRYSTAL FOR THE DETECTION OF IMMUNOREACTIONS IN BUFFER SOLUTIONS
    GEDDES, NJ
    PASCHINGER, EM
    FURLONG, DN
    EBARA, Y
    OKAHATA, Y
    THAN, KA
    EDGAR, JA
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1994, 17 (02) : 125 - 131
  • [5] INTERFACE ANALYSIS IN BIOSENSOR DESIGN
    GOPEL, W
    HEIDUSCHKA, P
    [J]. BIOSENSORS & BIOELECTRONICS, 1995, 10 (9-10) : 853 - 883
  • [6] UTILIZATION OF A SELF-ASSEMBLED PEPTIDE MONOLAYER FOR AN IMPEDIMETRIC IMMUNOSENSOR
    KNICHEL, M
    HEIDUSCHKA, P
    BECK, W
    JUNG, G
    GOPEL, W
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1995, 28 (02) : 85 - 94
  • [7] HIGH-FREQUENCY IMPEDANCE ANALYSIS OF QUARTZ-CRYSTAL MICROBALANCES .1. GENERAL-CONSIDERATIONS
    NOEL, MAM
    TOPART, PA
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (04) : 484 - 491
  • [8] Surface modification for direct immunoprobes
    Piehler, J
    Brecht, A
    Geckeler, KE
    Gauglitz, G
    [J]. BIOSENSORS & BIOELECTRONICS, 1996, 11 (6-7) : 579 - 590
  • [9] A 'mixed' self-assembled monolayer for an impedimetric immunosensor
    Rickert, J
    Gopel, W
    Beck, W
    Jung, G
    Heiduschka, P
    [J]. BIOSENSORS & BIOELECTRONICS, 1996, 11 (08) : 757 - 768
  • [10] A new affinity biosensor: Self-assembled thiols as selective monolayer coatings of quartz crystal microbalances
    Rickert, J
    Weiss, T
    Kraas, W
    Jung, G
    Gopel, W
    [J]. BIOSENSORS & BIOELECTRONICS, 1996, 11 (6-7) : 591 - 598