摘要
The prevention of catheter sepsis lies in a sound understanding of the routes through which catheters get contaminated. The catheter hub has been recognized as a portal for microorganisms causing catheter sepsis, particularly in central venous catheters inserted for >1 wk. Bacteria and fungi may reach the internal surface of the catheter connector during manipulation by hospital staff and then colonize the entire lumen of the catheter. Endoluminal contamination has diagnostic, therapeutic, and preventive implications. Some traditional preventive approaches (site care, subcutaneous cuffs and tunnels, maximal aseptic barriers at the time of catheter insertion, and external antiseptic of antibiotic coating) may fail because they focus solely on the skin as a source of bacteria. Hub-related catheter sepsis can be prevented by aseptic hub manipulation, appropriate junction protection, and by reducing the number of catheter lumens, side ports, three-way stopcocks, and changes of the infusion sets. Needleless systems must be evaluated in terms of their safety in preventing endoluminal contamination. A new disinfecting catheter hub incorporating an antiseptic barrier has been developed and reduced hub-related catheter sepsis by more than 90%. The endoluminal route of intravascular catheter contamination must be taken into account when designing strategies for the diagnosis and prevention of catheter-related sepsis. (C) Elsevier Science Inc. 1997.
引用
收藏
页码:S30 / S35
页数:6
相关论文
共 37 条
  • [1] SAFETY OF CHANGING INTRAVENOUS DELIVERY SYSTEMS AT LONGER THAN 24-HOUR INTERVALS
    BAND, JD
    MAKI, DG
    [J]. ANNALS OF INTERNAL MEDICINE, 1979, 91 (02) : 173 - 178
  • [2] BACTERIAL-CONTAMINATION OF INTRAVENOUS LINE SIDE PORTS OF DIFFERENT DESIGNS
    BRISMAR, B
    JORDAHL, L
    NYSTROM, B
    PETTERSSON, N
    [J]. CLINICAL NUTRITION, 1987, 6 (01) : 31 - 33
  • [3] A CONSERVATIVE PROCEDURE FOR THE DIAGNOSIS OF CATHETER-RELATED INFECTIONS
    CERCENADO, E
    ENA, J
    RODRIGUEZCREIXEMS, M
    ROMERO, I
    BOUZA, E
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1990, 150 (07) : 1417 - 1420
  • [4] USE OF TRIPLE-LUMEN SUBCLAVIAN CATHETERS FOR ADMINISTRATION OF TOTAL PARENTERAL-NUTRITION
    CLARKCHRISTOFF, N
    WATTERS, VA
    SPARKS, W
    SNYDER, P
    GRANT, JP
    [J]. JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1992, 16 (05) : 403 - 407
  • [5] A CONTROLLED TRIAL OF SCHEDULED REPLACEMENT OF CENTRAL VENOUS AND PULMONARY-ARTERY CATHETERS
    COBB, DK
    HIGH, KP
    SAWYER, RG
    SABLE, CA
    ADAMS, RB
    LINDLEY, DA
    PRUETT, TL
    SCHWENZER, KJ
    FARR, BM
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1992, 327 (15) : 1062 - 1068
  • [6] VENOUS INTERRUPTION FOR SEPTIC THROMBOPHLEBITIS
    CRANE, C
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1960, 262 (19) : 947 - 951
  • [7] BLOOD-STREAM INFECTIONS ASSOCIATED WITH A NEEDLELESS INTRAVENOUS-INFUSION SYSTEM IN PATIENTS RECEIVING HOME INFUSION THERAPY
    DANZIG, LE
    SHORT, LJ
    COLLINS, K
    MAHONEY, W
    SEPE, S
    BLAND, L
    JARVIS, WR
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 273 (23): : 1862 - 1864
  • [8] DECICCO M, 1989, LANCET, V2, P1258, DOI 10.1016/S0140-6736(89)91861-8
  • [9] AN OUTBREAK OF STAPHYLOCOCCUS-EPIDERMIDIS SEPTICEMIA
    DEITEL, M
    KRAJDEN, S
    SALDANHA, CF
    GREGORY, WD
    FUKSA, M
    CANTWELL, E
    [J]. JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1983, 7 (06) : 569 - 572
  • [10] PREDICTIVE VALUE OF SURVEILLANCE SKIN AND HUB CULTURES IN CENTRAL VENOUS CATHETERS SEPSIS
    FAN, ST
    TEOHCHAN, CH
    LAU, KF
    CHU, KW
    KWAN, AKB
    WONG, KK
    [J]. JOURNAL OF HOSPITAL INFECTION, 1988, 12 (03) : 191 - 198