Glow discharge mass spectrometric analysis of atmospheric particulate matter

被引:23
作者
Schelles, W [1 ]
Maes, KJR [1 ]
DeGendt, S [1 ]
VanGrieken, RE [1 ]
机构
[1] UNIV ANTWERP,DEPT CHEM,B-2610 ANTWERP,BELGIUM
关键词
D O I
10.1021/ac9509768
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A direct current (dc) glow discharge mass spectrometer has been used to analyze atmospheric particulate matter, The sample preparation used is simple and time-saving, The air is sucked by a pump through a single-orifice impactor stage, in which the aerosols are impacted on a metal support, forming a central spot. This metal plate is directly used as a cathode in a de glow discharge mass spectrometer. Evaluation of the sample loading and of the discharge parameters allowed us to optimize the signal intensity and to minimize its decrease, the latter being a consequence of its consumption by continuous sputtering in the discharge, The available aerosol analysis time could be prolonged to more than 3 h, a time span necessary to perform a multielement analysis using a magnetic sector instrument and long integration times. A NIST reference aerosol was measured to evaluate the quantitative analysis potential, The internal reproducibility was better than 10% RSD, and the limits of detection were estimated to be in the low ppm or sub ppm region, Even without the use of any standards or correction factors, glow discharge mass spectrometry could offer good semiquantitative results, based only on the use of an internal standard.
引用
收藏
页码:1136 / 1142
页数:7
相关论文
共 36 条
[1]  
BETTI M, 1995, 16152 EUR EN EUR COM, P188
[2]   ANALYSIS OF COAL FLY-ASH AND ENVIRONMENTAL MATERIALS BY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY - COMPARISON OF DIFFERENT DECOMPOSITION PROCEDURES [J].
BETTINELLI, M ;
BARONI, U ;
PASTORELLI, N .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (05) :485-489
[3]  
CADDLE RD, 1973, CHEM LOWER ATMOSPHER, P108
[4]  
Chapman B., 1980, GLOW DISCHARGE PROCE, P394
[5]   QUANTITATIVE-ANALYSIS OF IRON-RICH AND OTHER OXIDE-BASED SAMPLES BY MEANS OF GLOW-DISCHARGE MASS-SPECTROMETRY [J].
DEGENDT, S ;
SCHELLES, W ;
VANGRIEKEN, R ;
MULLER, V .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (09) :681-687
[6]   DESIGN AND CHARACTERIZATION OF A RADIO-FREQUENCY-POWERED GLOW-DISCHARGE SOURCE FOR DOUBLE-FOCUSING MASS SPECTROMETERS [J].
DUCKWORTH, DC ;
DONOHUE, DL ;
SMITH, DH ;
LEWIS, TA ;
MARCUS, RK .
ANALYTICAL CHEMISTRY, 1993, 65 (18) :2478-2484
[7]   RADIO-FREQUENCY POWERED GLOW-DISCHARGE ATOMIZATION IONIZATION SOURCE FOR SOLIDS MASS-SPECTROMETRY [J].
DUCKWORTH, DC ;
MARCUS, RK .
ANALYTICAL CHEMISTRY, 1989, 61 (17) :1879-1886
[8]  
EFIMOV AG, 1994, 17 ARB FESTK KFA JUL
[9]  
FINLAYSONPITTS B, 1986, ATMOSPHERIC CHEM FUN, P829
[10]  
*FIS INSTR EL AN, 1990, VG9000 SOFTW VERS 5