QUANTITATIVE-ANALYSIS OF IRON-RICH AND OTHER OXIDE-BASED SAMPLES BY MEANS OF GLOW-DISCHARGE MASS-SPECTROMETRY

被引:35
作者
DEGENDT, S [1 ]
SCHELLES, W [1 ]
VANGRIEKEN, R [1 ]
MULLER, V [1 ]
机构
[1] CTR RECH MET,B-4000 LIEGE,BELGIUM
关键词
GLOW DISCHARGE MASS SPECTROMETRY; IRON ORES; OXIDES; RELATIVE SENSITIVITY FACTORS;
D O I
10.1039/ja9951000681
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Glow discharge mass spectrometry has been applied to the analysis of iron-rich samples using a Fisons VG9000 mass spectrometer. Various iron ore reference materials were mixed in a 1+7 ratio with either copper or silver powder as a conducting host matrix. Both pin and flat geometry electrodes were prepared, Internal repeatability was seldom worse than 6%, and the external repeatability was typically better than 10% for the flat electrodes, and only slightly poorer for the pin electrodes, Linear calibration curves with correlation factors of 0.998 or better were obtained, Relative sensitivity factors were calculated and used to evaluate the effects of cooling, sample geometry and conducting host matrix, The variation in sensitivity factors for the non-conducting matrix materials under investigation (iron ores, sinters, firebrick, and bauxite) was usually <25%.
引用
收藏
页码:681 / 687
页数:7
相关论文
共 30 条
[1]   GLOW-DISCHARGE MASS-SPECTROMETRIC ANALYSIS OF TRACE-METALS IN PETROLEUM [J].
BARSHICK, CM ;
SMITH, DH ;
HACKNEY, JH ;
COLE, BA ;
WADE, JW .
ANALYTICAL CHEMISTRY, 1994, 66 (05) :730-734
[2]   ANALYSIS OF SOLUTION RESIDUES BY GLOW-DISCHARGE MASS-SPECTROMETRY [J].
BARSHICK, CM ;
DUCKWORTH, DC ;
SMITH, DH .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (01) :47-53
[3]   A PLASMA DISCHARGE SOURCE-MASS SPECTROMETER FOR INORGANIC ANALYSIS [J].
CANTLE, JE ;
HALL, EF ;
SHAW, CJ ;
TURNER, PJ .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 46 (JAN) :11-13
[4]   NEW TECHNIQUE FOR ELEMENTAL ANALYSIS OF THIN SURFACE LAYERS OF SOLIDS [J].
COBURN, JW ;
KAY, E .
APPLIED PHYSICS LETTERS, 1971, 19 (09) :350-&
[6]   PARAMETER EVALUATION FOR THE ANALYSIS OF OXIDE-BASED SAMPLES WITH RADIO-FREQUENCY GLOW-DISCHARGE MASS-SPECTROMETRY [J].
DEGENDT, S ;
VANGRIEKEN, RE ;
OHORODNIK, SK ;
HARRISON, WW .
ANALYTICAL CHEMISTRY, 1995, 67 (06) :1026-1033
[7]  
DOGAN M, 1973, FRESEN Z ANAL CHEM, V263, P1
[8]   RADIOFREQUENCY CAVITY ION-SOURCE IN SOLIDS MASS-SPECTROMETRY [J].
DONOHUE, DL ;
HARRISON, WW .
ANALYTICAL CHEMISTRY, 1975, 47 (09) :1528-1531
[9]   ANALYSIS OF SOILS BY GLOW-DISCHARGE MASS-SPECTROMETRY [J].
DUCKWORTH, DC ;
BARSHICK, CM ;
SMITH, DH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (06) :875-879
[10]   DESIGN AND CHARACTERIZATION OF A RADIO-FREQUENCY-POWERED GLOW-DISCHARGE SOURCE FOR DOUBLE-FOCUSING MASS SPECTROMETERS [J].
DUCKWORTH, DC ;
DONOHUE, DL ;
SMITH, DH ;
LEWIS, TA ;
MARCUS, RK .
ANALYTICAL CHEMISTRY, 1993, 65 (18) :2478-2484