Comparison of four tests to assess inhibition of platelet function by clopidogrel in stable coronary artery disease patients

被引:122
作者
Lordkipanidze, Marie [1 ,2 ,3 ]
Pharand, Chantal [1 ,2 ,3 ]
Nguyen, Thuy Anh [2 ,3 ]
Schampaert, Erick [1 ,4 ,5 ]
Palisaitis, Donald A. [1 ,4 ,5 ]
Diodati, Jean G. [1 ,4 ,5 ]
机构
[1] Hop Sacre Coeur, Res Ctr, Montreal, PQ H4J 1C5, Canada
[2] Univ Montreal, Fac Pharm, Montreal, PQ H3C 3J7, Canada
[3] Hop Sacre Coeur, Dept Pharm, Montreal, PQ H4J 1C5, Canada
[4] Univ Montreal, Fac Med, Montreal, PQ H3C 3J7, Canada
[5] Hop Sacre Coeur, Div Cardiol, Montreal, PQ H4J 1C5, Canada
关键词
Platelet function testing; Platelet aggregation; Platelet analyzers; Clopidogrel; Responsiveness;
D O I
10.1093/eurheartj/ehn419
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims We investigated the comparability of platelet function tests in quantifying platelet inhibition achieved by clopidogrel. Methods and results This pre-specified substudy of a randomized, double-blind trial included 116 patients with stable coronary artery disease requiring diagnostic angiography. Patients received clopidogrel for 1 (300 or 600 mg) or 7 days (300 + 75 or 150 mg daily) before the procedure. Blood samples obtained before clopidogrel initiation and before diagnostic coronary angiography were assayed using light transmission aggregometry [adenosine diphosphate (ADP) 5 and 20 mM as the agonist], whole-blood aggregometry (ADP 5 and 20 mM), PFA-100w (Collagen-ADP cartridge), and VerifyNow (R) P2Y12. Although all assays studied were found sensitive to clopidogrel ingestion, none could distinguish categorically between patients who had, or not, ingested clopidogrel. Agreement between assays to identify patients with insufficient inhibition of platelet aggregation by clopidogrel was low. Conclusion The assessment of platelet function inhibition by clopidogrel is highly test-specific. Decision to increase clopidogrel dosage may vary on the basis of the assay used, thus highlighting the need for unambiguous guidelines with respect to assay selection, as platelet function assays are not interchangeable. At present, platelet function testing evaluating clopidogrel efficacy cannot be recommended in routine clinical practice.
引用
收藏
页码:2877 / 2885
页数:9
相关论文
共 30 条
[1]   Quantifying the effect of antiplatelet therapy -: A comparison of the platelet function Analyzer (PFA-100®) and modified thromboelastography (mTEG®) with lightt transmission platelet aggregometry [J].
Agarwal, Seema ;
Coakely, Margaret ;
Reddy, Kalpana ;
Riddell, Anne ;
Mallett, Susan .
ANESTHESIOLOGY, 2006, 105 (04) :676-683
[2]   The platelet inhibiting effect of a clopidogrel bolus dose in patients on long-term acetylsalicylic acid treatment [J].
Alstrom, Ulrica ;
Tyden, Hans ;
Oldgren, Jonas ;
Siegbahn, Agneta ;
Stahle, Elisabeth .
THROMBOSIS RESEARCH, 2007, 120 (03) :353-359
[3]  
Baigent C, 2002, BMJ-BRIT MED J, V324, P71, DOI 10.1136/bmj.324.7329.71
[4]  
Bassand JP, 2007, EUR HEART J, V28, P1598, DOI 10.1093/eurheartj/ehm161
[5]   Applying the right statistics: analyses of measurement studies [J].
Bland, JM ;
Altman, DG .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 22 (01) :85-93
[6]   Can platelet aggregometry be standardized? [J].
Breddin, HK .
PLATELETS, 2005, 16 (3-4) :151-158
[7]  
Chatburn R L, 1996, AANA J, V64, P261
[8]   Approach to the assessment of platelet function: Comparison between optical-based platelet-rich plasma and impedance-based whole blood platelet aggregation methods [J].
Dyszkiewicz-Korpanty, AM ;
Frenkel, EP ;
Sarode, R .
CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2005, 11 (01) :25-35
[9]   Clopidogrel anti-platelet effect:: An evaluation by optical aggregometry, impedance aggregometry, and the Platelet Function Analyzer (PFA-100™) [J].
Dyszkiewicz-Korpanty, Anna ;
Olteanu, Horatiu ;
Frenkel, Eugene P. ;
Sarode, Ravindra .
PLATELETS, 2007, 18 (07) :491-496
[10]   Monitoring of clopidogrel action: Comparison of methods [J].
Geiger, J ;
Teichmann, L ;
Grossmann, R ;
Aktas, B ;
Steigerwald, U ;
Walter, U ;
Schinzel, R .
CLINICAL CHEMISTRY, 2005, 51 (06) :957-965