On-chip electrochemical detection of CdS quantum dots using normal and multiple recycling flow through modes

被引:22
作者
Medina-Sanchez, Mariana [2 ,3 ]
Miserere, Sandrine [2 ,3 ]
Marin, Sergio [2 ,3 ]
Aragay, Gemma [2 ,3 ]
Merkoci, Arben [1 ,2 ,3 ]
机构
[1] ICREA, Barcelona, Spain
[2] Inst Catala Nanotecnol, Nanobioelect & Biosensors Grp, Barcelona, Spain
[3] Univ Autonoma Barcelona, Bellaterra, Spain
关键词
NANOPARTICLES;
D O I
10.1039/c2lc00007e
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A flexible hybrid polydimethylsiloxane (PDMS)-polycarbonate (PC) microfluidic chip with integrated screen printed electrodes (SPE) was fabricated and applied for electrochemical quantum dots (QDs) detection. The developed device combines the advantages of flexible microfluidic chips, such as their low cost, the possibility to be disposable and amenable to mass production, with the advantages of electrochemistry for its facility of integration and the possibility to miniaturize the analytical device. Due to the interest in biosensing applications in general and particularly the great demand for labelling alternatives in affinity biosensors, the electrochemistry of cadmium sulfide quantum dots (CdS QDs) is evaluated. Square wave anodic stripping voltammetry (SWASV) is the technique used due to its sensitivity and low detection limits that can be achieved. The electrochemical as well as the microfluidic parameters of the developed system are optimized. The detection of CdS QDs in the range between 50 to 8000 ng mL(-1) with a sensitivity of 0.0009 mu A/(ng mL(-1)) has been achieved. In addition to the single in-chip flow through measurements, the design of a recirculation system with the aim of achieving lower detection limits using reduced volumes (25 mu L) of sample was proposed as a proof-of-concept.
引用
收藏
页码:2000 / 2005
页数:6
相关论文
共 21 条
[1]   On-line trace metal determination by pre-concentration on immobilized 8-quinolinol with flow recycling anodic stripping voltammetry [J].
Armalis, S ;
Johansson, G .
ANALYTICA CHIMICA ACTA, 1997, 339 (1-2) :155-159
[2]  
Baldwin RP, 2000, ELECTROPHORESIS, V21, P4017, DOI 10.1002/1522-2683(200012)21:18<4017::AID-ELPS4017>3.0.CO
[3]  
2-5
[4]   Synthesis, structure and spectroscopic characterization of water-soluble CdS nanoparticles [J].
Barglik-Chory, C ;
Buchold, D ;
Schmitt, M ;
Kiefer, W ;
Heske, C ;
Kumpf, C ;
Fuchs, O ;
Weinhardt, L ;
Stahl, A ;
Umbach, E ;
Lentze, M ;
Geurts, J ;
Müller, G .
CHEMICAL PHYSICS LETTERS, 2003, 379 (5-6) :443-451
[5]   Quantum dot bioconjugates for ultrasensitive nonisotopic detection [J].
Chan, WCW ;
Nie, SM .
SCIENCE, 1998, 281 (5385) :2016-2018
[6]   HYDRODYNAMIC VOLTAMMETRY WITH MICROELECTRODES - CHANNEL MICROBAND ELECTRODES - THEORY AND EXPERIMENT [J].
COMPTON, RG ;
FISHER, AC ;
WELLINGTON, RG ;
DOBSON, PJ ;
LEIGH, PA .
JOURNAL OF PHYSICAL CHEMISTRY, 1993, 97 (40) :10410-10415
[7]   Microfluidic platforms for lab-on-a-chip applications [J].
Haeberle, Stefan ;
Zengerle, Roland .
LAB ON A CHIP, 2007, 7 (09) :1094-1110
[8]   A cyclo olefin polymer microfluidic chip with integrated gold microelectrodes for aqueous and non-aqueous electrochemistry [J].
Illa, Xavi ;
Ordeig, Olga ;
Snakenborg, Detlef ;
Romano-Rodriguez, Albert ;
Compton, Richard G. ;
Kutter, Jorg P. .
LAB ON A CHIP, 2010, 10 (10) :1254-1261
[9]   Nano-bio-chips for high performance multiplexed protein detection: Determinations of cancer biomarkers in serum and saliva using quantum dot bioconjugate labels [J].
Jokerst, Jesse V. ;
Raamanathan, Archana ;
Christodoulides, Nicolaos ;
Floriano, Pierre N. ;
Pollard, Amanda A. ;
Simmons, Glennon W. ;
Wong, Jorge ;
Gage, Carole ;
Furmaga, Wieslaw B. ;
Redding, Spencer W. ;
McDevitt, John T. .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (12) :3622-3629
[10]   Electrochemical coding for multiplexed immunoassays of proteins [J].
Liu, GD ;
Wang, J ;
Kim, J ;
Jan, MR ;
Collins, GE .
ANALYTICAL CHEMISTRY, 2004, 76 (23) :7126-7130