Longevity of implantable cardioverter-defibrillators: implications for clinical practice and health care systems

被引:50
作者
Biffi, Mauro [1 ]
Ziacchi, Matteo [1 ]
Bertini, Matteo [1 ]
Sangiorgi, Diego [1 ]
Corsini, Daniela [2 ]
Martignani, Cristian [1 ]
Diemberger, Igor [1 ]
Boriani, Giuseppe [1 ]
机构
[1] Univ Bologna, Policlin S Orsola Malpighi, Inst Cardiol, I-40138 Bologna, Italy
[2] Univ Bologna, Policlin S Orsola Malpighi, Dept Pharm, I-40138 Bologna, Italy
来源
EUROPACE | 2008年 / 10卷 / 11期
关键词
Implantable cardioverter-defibrillator; Battery longevity; Device cost;
D O I
10.1093/europace/eun240
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Comparative studies on the longevity of implantable cardioverter-defibrillators (ICDs) among different manufacturers have never been reported. Longevity of ICD devices implanted from 1 January 2000 to 31 December 2002 was prospectively investigated according to their type and manufacturer. Methods and results Longevity of single-chamber (SC), double-chamber (DC), and biventricular (CRT-D) ICDs from Medtronic (MDT), Guidant (GDT), and St Jude Medical (SJM) was measured in all the patients who required device replacement. The observation follow-up ended on 31 December 2007; patients who died prematurely or were transplanted before battery exhaustion were excluded from the analysis. Factors associated with longevity (number of delivered shocks, pacing activity) were researched. One hundred and fifty-three patients received an ICD in the abovementioned period. Six underwent heart transplantation, and 23 died before device replacement; 80 had an SC device, 59 had DC device, and 14 had CRT-D device. Longevity of MDT was superior to GDT and SJM, replacement rates being, respectively, 42%, 95.3%, and 97.2%. Only MDT manufacturers and SC type were associated with greater ICD longevity. Longevity had an impact on the cost/month of treatment of replaced ICDs. Conclusion Battery longevity is significantly different among manufacturers. ICD cost is strictly dependent on device longevity, whereas device up-front cost is of limited clinical meaning. Appropriate assessment of cost-effectiveness should be based on ICD longevity in the real-life scenario.
引用
收藏
页码:1288 / 1295
页数:8
相关论文
共 38 条
[1]   Clinical and economic implications of the multicenter automatic defibrillator implantation trial-II [J].
Al-Khatib, SM ;
Anstrom, KJ ;
Eisenstein, EL ;
Peterson, ED ;
Jollis, JG ;
Mark, DB ;
Li, Y ;
O'Connor, CM ;
Shaw, LK ;
Califf, RM .
ANNALS OF INTERNAL MEDICINE, 2005, 142 (08) :593-600
[2]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[3]   Left ventricular pacing by automatic capture verification [J].
Biffi, Mauro ;
Bertini, Matteo ;
Ziacchi, Matteo ;
Boriani, Giuseppe .
EUROPACE, 2007, 9 (12) :1177-1181
[4]   Atrial threshold variability: Implications for automatic atrial stimulation algorithms [J].
Biffi, Mauro ;
Spitali, Girolamo ;
Silvetti, Massimo Stefano ;
Argnani, Selina ;
Rubino, Ida ;
Fontana, Pierluigi ;
Barbato, Gaetano ;
Mazzini, Elena ;
de Santo, Tiziana ;
Drago, Fabrizio ;
Boriani, Giuseppe .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (12) :1445-1454
[5]   Role of ventricular autocapture function in increasing longevity of DDDR pacemakers: a prospective study [J].
Boriani, G ;
Rusconi, L ;
Biffi, M ;
Pavia, L ;
Sassara, M ;
Malfitano, D ;
Bongiorni, MG ;
Padeletti, L ;
Filice, I ;
Sanfelici, D ;
Maffei, P ;
Vicentini, A ;
Branzi, A .
EUROPACE, 2006, 8 (03) :216-220
[6]   A randomized study of the prevention of sudden death in patients with coronary artery disease [J].
Buxton, AE ;
Lee, KL ;
Fisher, JD ;
Josephson, ME ;
Prystowsky, EN ;
Hafley, G .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (25) :1882-1890
[7]   The cost of implantable defibrillators: perceptions and reality [J].
Camm, John ;
Klein, Helmut ;
Nisam, Seah .
EUROPEAN HEART JOURNAL, 2007, 28 (04) :392-397
[8]   Hybrid cathode lithium batteries for implantable medical applications [J].
Chen, Kaimin ;
Merritt, Donald R. ;
Howard, William G. ;
Schmidt, Craig L. ;
Skarstad, Paul A. .
JOURNAL OF POWER SOURCES, 2006, 162 (02) :837-840
[9]   Evolution of power sources for implantable cardioverter defibrillators [J].
Crespi, AM ;
Somdahl, SK ;
Schmidt, CL ;
Skarstad, PM .
JOURNAL OF POWER SOURCES, 2001, 96 (01) :33-38
[10]   Automated left ventricular capture management [J].
Crossley, George H. ;
Mead, Hardwin ;
Kleckner, Karen ;
Sheldon, Todd ;
Davenport, Lynn ;
Harsch, Manya R. ;
Parikh, Purvee ;
Ramza, Brian ;
Fishel, Robert ;
Bailey, J. Russell .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (10) :1190-1200