Role of ventricular autocapture function in increasing longevity of DDDR pacemakers: a prospective study

被引:41
作者
Boriani, G
Rusconi, L
Biffi, M
Pavia, L
Sassara, M
Malfitano, D
Bongiorni, MG
Padeletti, L
Filice, I
Sanfelici, D
Maffei, P
Vicentini, A
Branzi, A
机构
[1] Univ Bologna, Azienda Osped Policlin S Orsola Malpighi, Inst Cardiol, I-40138 Bologna, Italy
[2] Osped Ceccarini, Riccione, Italy
[3] Osped Piemonte, Messina, Italy
[4] Osped Grande Infermi, Viterbo, Italy
[5] Osped Gravina, Caltagirone, Italy
[6] Osped Cisanello, Pisa, Italy
[7] Osped Careggi, Florence, Italy
[8] Osped San Paolo, Savona, Italy
[9] Osped Santa Corona, Pietra Ligure, Italy
[10] Osped Sanremo, San Remo, Italy
[11] Clin Pederzoli, Peschiera Garda, Italy
来源
EUROPACE | 2006年 / 8卷 / 03期
关键词
autocapture; cardiac pacing; cost-effectiveness; stimulation threshold;
D O I
10.1093/europace/euj027
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Autocapture is an algorithm for automatic adaptation of ventricular output to capture threshold. The aim of this prospective study was to estimate the effects of ventricular Autocapture algorithm on DDD-DDDR pacemaker longevity. Methods and results Eighty-three patients implanted with a DDD-DDDR pacemaker (Affinity or Entity; St Jude Medical, USA) were enrolled and the Autocapture function was activated pre-discharge. Ventricular pulse duration was randomly programmed at 0.3 or 0.4 ms, with a cross-over at 8-12 weeks and again at 13-14 months. Diagnostic data were retrieved from device memory and by calculating battery current drain from long-term threshold recordings; device longevity was estimated at the following settings: Autocapture with a pulse duration of 0.3 and 0.4 ms, respectively, standard output (3.5 V, 0.4 ms) and conventional tow output programming (2.5 V, 0.4 ms). According to a series of assumptions, Autocapture was associated with a 55-60% increase in estimated device longevity compared with standard output programming and a 6-7% increase in longevity compared with low output programming. No significant differences were found between Autocapture programmed with a pulse duration of 0.3 or 0.4 ms. In projections to a 10-year follow-up, use of the Autocapture function resulted in a 42% reduction in pacing-related estimated costs compared with standard output programming at 3.5 V, 0.4 ms. Conclusion Pacing with constant adaptation of ventricular output in dual-chamber devices has the potential to increase generator longevity and to reduce sizeably pacing-related costs compared with standard programming.
引用
收藏
页码:216 / 220
页数:5
相关论文
共 19 条
[1]   Energy parameters in cardiac pacing should be abandoned [J].
Barold, SS ;
Stokes, K ;
Byrd, CL ;
McVenes, R .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (01) :112-121
[2]   Atrial evoked response integral for automatic capture verification in atrial pacing [J].
Boriani, G ;
Biffi, M ;
Cameron, D ;
Datteri, S ;
Snell, J ;
Holmström, N ;
Park, E ;
Bornzin, GA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (01) :248-252
[3]  
Boriani G, 2000, PACE, V23, P1783
[4]   Long-term survival after pacemaker implantation - Prognostic importance of gender and baseline patient characteristics [J].
Brunner, M ;
Olschewski, M ;
Geibel, A ;
Bode, C ;
Zehender, M .
EUROPEAN HEART JOURNAL, 2004, 25 (01) :88-95
[5]   Automatic adjustment of pacemaker stimulation output correlated with continuously monitored capture thresholds:: A multicenter study [J].
Clarke, M ;
Liu, B ;
Schüller, H ;
Binner, L ;
Kennergren, C ;
Guerola, M ;
Weinmann, P ;
Ohm, OJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (08) :1567-1575
[6]  
Dohrmann M L, 1985, Cardiol Clin, V3, P527
[7]  
FURMAN S, 1993, PRACTICE CARDIAC PAC, P68
[8]   A cardiac evoked response algorithm providing threshold tracking: A North American multicenter study [J].
Lau, C ;
Cameron, DA ;
Nishimura, SC ;
Ahern, T ;
Freedman, RA ;
Ellenbogen, K ;
Greenberg, S ;
Baker, J ;
Meacham, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (06) :953-959
[9]   A prospective multicenter study on the safety of a pacemaker with automatic energy control:: Influence of the electrical factor on chronic stimulation threshold. [J].
Madrid, AH ;
Olagüe, J ;
Cercas, A ;
Del Ojo, JL ;
Muñoz, F ;
Moro, C ;
Sanz, O .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (09) :1359-1364
[10]   Alternative projections of mortality and disability by cause 1990-2020: Global burden of disease study [J].
Murray, CJL ;
Lopez, AD .
LANCET, 1997, 349 (9064) :1498-1504